Setec ST-III Series Скачать руководство пользователя страница 5

Accessories

Accessories provided with this product are:

1.

User Manual

Introduction

These instructions detail the installation and operation requirements for the ST20­
III & ST35­III power supplies. These have been designed for operation in RV’s 
providing a DC power system, with optional battery back up. 

The units operate from 240Vac and provide an isolated 13.65Vdc output at 20A 
and 35A respectively for powering the load and charging of batteries. All the 
necessary protection and operating features for the load and batteries are 
provided. An optional DC input is also provided to enable charging of batteries 
and powering of the load from an ex13.8V DC power source.

The units are fully enclosed ready for direct wall mounting. All connections are at 
the rear of unit providing convenient wiring and installation. User access to all 
load and battery fusing has been provided from the front of the unit.

Operation

Safety:

 Refer to the installation section before operating. Correct installation is 

the most critical factor in ensuring the safe use of the power supply. If every 
consideration of these instructions has been satisfied the power supply will be 
safe to operate.

If the AC supply cord is damaged it must be replaced by the manufacturer, its 
service agent or similarly qualified persons in order to avoid hazard.

The unit is rated to charge a single 12V (up to 6 cells) lead acid battery at 100Ahr 
Capacity.

5

Содержание ST-III Series

Страница 1: ...ST III Series POWER SUPPLY Owner s Manual Please read the Installation section of this manual before installing the product...

Страница 2: ...or suitability of the information contained in this manual Setec Pty Ltd accepts no liability for any loss or damage which may occur as a result of improper or unsafe use of its products Warranty is...

Страница 3: ...nctional Diagram 6 ST III Basics 6 Installing The ST III Power Supply 9 Wiring Up 10 Servicing 12 Specifications 13 Battery Management 14 Frequently Asked Questions 15 Anderson Plug Operation 16 After...

Страница 4: ...not cause short circuits Remove any personal metal adornment such as a chain watch or ring which could cause short circuits and personal injury CAUTION Failure to observe these instructions properly m...

Страница 5: ...and powering of the load from an external 13 8V DC power source The units are fully enclosed ready for direct wall mounting All connections are at the rear of unit providing convenient wiring and ins...

Страница 6: ...the load current plus battery current is equal or less than the maximum output current The charging current will be reduced in situations where the difference between the rated output current and the...

Страница 7: ...loads NOTE When the battery is isolated from the loads using the battery isolate switch it will NOT charge at the 10 15 A rate even if the mains is connected to the power supply In this condition it w...

Страница 8: ...of power supply Serious power supply damage or internal explosion may occur If a flat 12 volt battery has to be charged using the generators 12 volt output it should first be disconnected from the pow...

Страница 9: ...CAUTION Do not install unit in same compartment as batteries or flammable material such as petrol Ensure that the installation meets the ventilation requirements above Mechanical and Mounting Depth o...

Страница 10: ...put Connections Connectors are 0 8 x 6 3mm QC tabs Use mating QC connector suitable for cable size Connector pin out is shown below 10 F4 F5 F6 F7 F8 FBATT L1 L2 L3 L4 L5 VBATT Fuse Panel ve terminals...

Страница 11: ...cedures Battery should be disconnected as per the following steps 1 Turn power supply off and all 12 volt equipment connected to power supply 2 Disconnect negative battery terminal connection to Batt...

Страница 12: ...ause short circuits Remove any personal metal adornment such as a chain watch or ring which could cause short circuits and personal injury Do not charge non rechargeable batteries Failure to do so may...

Страница 13: ...ection ST20 III 20A to 25A load battery current ST35 III 35A to 38A load battery current Battery Current Limit 10A 1A ST20 III 15A 1A ST35 III Battery Connect Disconnect Connect 10 50 0 2V Input Mains...

Страница 14: ...s float charging current VFloat 13 65V the unit utilises a storage mode voltage VStore 13 25V when no activity on the battery is detected This extends the battery life During store mode the unit exits...

Страница 15: ...age and may not provide the voltage required to run the ST III ST III When the Aux IN terminal is used from the tow car is this a straight through connection to the battery The AUX in provides another...

Страница 16: ...Trailer Plug Operation To wire the ST III to the car follow the diagrams for the different plug types For more information please contact your dealer 16...

Страница 17: ...After sales Service WARNING Do not disassemble modify or repair the unit Doing so may result in electric shocks or fire Repairs and After sales Service Consult your Setec dealer 17...

Страница 18: ...im under this warranty you must a Ensure the product is installed by a suitably qualified person and is installed in accordance with this Owner s Manual and any applicable Australian Standard b The pr...

Страница 19: ...000000 Rev 5A DESIGNED AND MANUFACTURED IN AUSTRALIA...

Отзывы: