Sesamo MILLENNIUM ADVANCED SELECTOR Скачать руководство пользователя страница 6

5

The menus are structured in a hierarchical manner, and thus each menu may contain submenus; each time the user exits
from a submenu he enters the immediately previous menu in the hierarchical scheme.

Arrows of this type indicate that it is possible to scroll through the menu
both with the SCROLL UP key and with the SCROLL DOWN key.

This means pressing the OK key.

Arrows of this type indicate that by pressing the OK key the user moves
into a menu of a different hierarchical level.

Main Menu

Management Menu (1)

There are two different kind of password: the one for the final user, and the universal password normally used by the
installer. The first by default corresponds to 0000 and can be changed through the Setting Menu; menus shown in gray in
the charts are neither visible nor accessible with this password. The second password is 5392 and cannot be altered; with
this password all menus are accessible.

To enter into the management menu it is necessary to input the user password:

to input, for example, the password 

5724

proceed as indicated in the figure:

To select the desired number use the SCROLL UP and SCROLL DOWN keys.

In Multi Slave mode, whenever the Management Menu is accessed, the user is asked to specify on which door he wants to
operate, among those connected to the selector.

Key

Key

OK

Installer Password (universal) = 5392
Default Password (user) = 0000

Содержание MILLENNIUM ADVANCED SELECTOR

Страница 1: ...I N S T A L L A T I O N M A N U A L MILLENNIUM ADVANCED SELECTOR...

Страница 2: ...the use man ual and all the information necessary for the cor rect use in automatic operation manual operation also in the case of electric locking and in emer gencies This device has been exclusivel...

Страница 3: ...terminal box is turned downwards Position the cover by centering it on the appropriate supports C Fig 2 so that the led indicators are housed correctly in the appropriate seats Pay particular attentio...

Страница 4: ...ted in the figure For the connection use a screened cable with 4 wires of 0 22 mm max 50 m connect the 4 internal conductors of the screened cable respecting the corre spondences indicated by the scre...

Страница 5: ...ent closing of the door wings The electric locking system if present blocks the door wings every time that these reach the position of complete closure Partial opening with entry exit radar like the E...

Страница 6: ...and the universal password normally used by the installer The first by default corresponds to 0000 and can be changed through the Setting Menu menus shown in gray in the charts are neither visible nor...

Страница 7: ...6 Management Menu continued Language Choice Menu 1 1 Permits the user to select the language used in the functions menu Indicates the value currently set...

Страница 8: ...tal opening Setting range 10 90 Default value 50 Anti crushing Represents the anti crushing sensibility The values may be set separately for the opening ANTI CRUSH OP and the closing ANTI CRUSH CL Set...

Страница 9: ...he automatism with this menu it is possible to choose if the Stop position is a complete closure or a complete opening Password Menu 1 3 2 Permits the user to modify the User Password For the input lo...

Страница 10: ...Porta 13 1 0 1 1 Porta 14 0 1 1 1 Porta 15 1 1 1 1 This menu per mits to activate the multi slave mode so that a number of differ ent doors up to a maximum of 15 can be con trolled by a single select...

Страница 11: ...the system s continues operating normally hitting any key will erase the display but the request will reappear two days later The request will disappear definitively only once the maintenance routine...

Страница 12: ...he control card date of last mainte nance number of breakdowns last error number of battery interventions history of the errors etc This operation must be executed every time that an assistance interv...

Страница 13: ...igure the inputs and outputs of the control center in particular it is possible to define the electric state of each input Normally Open or Normally Closed independently of the Default condition For e...

Страница 14: ...the Display Calendar Menu 1 4 This menu permits the user to set changes of the operation logic events in automatic mode at a fixed hour and day of the week up to a maximum of 4 events daily It is poss...

Страница 15: ...r events may be set For each event it is possible to set STATE indicates if the event is activat ed or not HOUR indicates the hour of the event beginning MINUTES indicates the minutes of the event beg...

Страница 16: ...eroed Manoeuvre is understood as a complete cycle of opening and closing a possible inversion increases the number of manoeuvres BATTERY INTERV indicates the number of times in which the centre has be...

Отзывы: