9
Interblock Menu (1.3.3)
Permits the user to
configure the automatism in
MASTER or SLAVE mode in
the interblocked operation.
The submenu SIGNAL
MEMORY permits the user
to use the special interblock
version. (Soon to be
activated.)
Multi Slave Menu (1.3.4)
S5 S6 S7 S8
Porta
1
1
0
0
0
Porta
2
0
1
0
0
Porta
3
1
1
0
0
Porta
4
0
0
1
0
Porta
5
1
0
1
0
Porta
6
0
1
1
0
Porta
7
1
1
1
0
Porta
8
0
0
0
1
Porta
9
1
0
0
1
Porta
10
0
1
0
1
Porta
11
1
1
0
1
Porta
12
0
0
1
1
Porta
13
1
0
1
1
Porta
14
0
1
1
1
Porta
15
1
1
1
1
This menu per-
mits to activate
the multi slave
mode, so that a
number of differ-
ent doors (up to
a maximum of
15) can be con-
trolled by a single
selector.
Once the multi
slave mode is
activated, it must
be decided which
ones and how
many doors are
connected to the
selector. This can
be done setting
the Dip Switch
located on the
Millennium elec-
tronic card,
according with
the table on this page..
Don’t forget to correctly adjust each
card as shown in the table and to use a dif-
ferent address for each card; otherwise multi
slave mode will not work properly.
Indicates the
value
currently set
DIPSWITCH ON/OFF