background image

5(17)

Servodan A/S | Tel +45 7442 4726 | Fax + 45 7442 4035 | [email protected] | www.servodan.com

On

1 2

4

3

Fig. 8

Fig. 6

Light 1
On/Off

Lock/

unlock

LED

On/Off

Test

On/Off

Learn actual lux

Lux zone 1

30

Lux

100 

Lux

300
Lux

1000

Lux

2000

Lux

600
Lux

0,4

0,6

0,8

1,0

1,4

1,6

1,2

Lux zone 2

Pulse

2min

5min

Time 1

Time 2

10min

15min

30min

Reset

Lux

On/Off

Time 3

Light 2
On/Off

Factor of

lux zone 1

Time

Factory setting

On

1 2

4

3

Minimum sensitivity

Low sensitivity

High sensitivity

Maximum sensitivity

On

1 2

4

3

On

1 2

4

3

On

1 2

4

3

On

1 2

4

3

App. Auto

App. Manual

App. Auto, without light sensor

App. Manual, without light sensor

On

1 2

4

3

On

1 2

4

3

On

1 2

4

3

= On

= OFF

Tilbehør

Accessory

Zubehör

Accessoire

Advarsel:

 Indbygning og montering af elektriske apparater må kun foretages af aut. elinstallatør. Ved fejl eller driftforstyrelser kontakt den aut. 

elinstallatør. Se altid den seneste revision på www.servodan.dk. 

! Ret til ændringer forbeholdes !

Warning:

 Installation and assembly of electrical equipment must be carried out by qualifi ed electricians. 

Contact a qualifi ed electrician in the event of 

fault or breakdown. Always see the latest revision on www.servodan.com 

! Reserving the right to make changes !

Achtung:

 Einbau und Montage elektrischer Geräte dürfen nur durch Elektrofachkräfte erfolgen. 

Wenden Sie sich bei Störungen bzw. Ausfall an einen 

Elektrofachkraft. Siehe immer die letzte Revision auf www.servodan.com 

! Änderungen vorbehalten !

Avertissement:

 L’installation et le montage d’appareils électriques doivent exclusivement être exécutés par un électricien agréé. En cas de défaut ou de perturbation du 

fonctionnement, contacter un installateur électricien agréé. Il convient de toujours vérifi er les dernières mises à jour sur www.servodan.dk. 

! Sous réserve de modifi cations !

41-920

41-981

Fig. 5

Daylight

Zone 2

Zone 1

= Pushbutton door

= Movement sensor

= Luminaire

Fig. 7

Auto

Auto, without

light sensor

Manuel, without

light sensor

Manuel

Auto On

Auto Off

Manuel Off

Manuel On

Test via DIP

Push button

Extra PIR

App.

Func.

X

X

(X)

(X)

X

X

X

X

X

(X)

X

X

(X)

X

X

X

Option

Option

Option

Option

Option

Option

Required

Required

Содержание 41-445

Страница 1: ...tilslutning er bev gelsessensoren funktionsklar efter ca 1 min opvarmningstid For tilslutning af PIR og tryk se brugervejledning for Power Pack type 41 981 Ordliste App Applikation angiver hvilken fun...

Страница 2: ...Manuel uden lyssensor DIP 3 On DIP4 On Fig 6 7 Sensoren g r i 5 minutters g test funktion efter power up herefter Manuel t nd via betjeningstryk automatisk sluk via bev gelsessensor Betjeningstryk sk...

Страница 3: ...ght 1 og 2 On Off aktiveres aktiveres ogs svagstr ms rel et 8 9 p 41 981 Svagstr msrel et vil v re aktiveret On s l nge der registreres aktivitet og udkoblingstiden 2 timer ikke er udl bet LED On Off...

Страница 4: ...vodan dk www servodan com Fig 1 Fig 2 Fig 3 O 90 32 16 24 4 0m 3 5m 3 0m 2 5m 7m 8m 12m 10m 1 2 57 63 mm 55mm for PL box 60mm for Euro box Pin 1 Pin 6 Fig 4 Pin 1 Pin 2 Pin 3 Switch Slave Pin 4 Ch 1 N...

Страница 5: ...tallation and assembly of electrical equipment must be carried out by qualified electricians Contact a qualified electrician in the event of fault or breakdown Always see the latest revision on www se...

Страница 6: ...e seen in Fig 4 After connection to the power supply the movement sensor will be ready to operate after approximately 1 min warm up time For details of how to connect the PIRs and switch see the user...

Страница 7: ...5 minute walk test mode after powering up followed by Manual switch on by operating the pushbutton automatic switch off via movement sensor Pushbutton must be connected The light switches off automat...

Страница 8: ...ed the low voltage relay is also activated 8 9 on 41 981 The low voltage relay will remain active On aslong as activity is detected and the cut off time 2 hours has not run out LED On Off Switches the...

Страница 9: ...zu sehen Nach dem Einschalten der Spannungsversorgung ist der Bewegungsmelder nach ca 1 Minute Aufw rmzeit betriebsbereit Zum Anschluss von PIR und Druckschaltern siehe die Gebrauchsanweisung des Powe...

Страница 10: ...tsensor DIP 3 On DIP4 On Fig 6 7 Der Sensor geht nach dem Hochfahren 5 Minuten lang in die Gehtest Funktion ber dann Manuelles Einschalten ber Bedientaste automatisches Ausschalten ber Bewegungsmelder...

Страница 11: ...Lock unlock benutzt Beim Aktivieren von Light 1 und 2 On Off wird auch das Schwachstromrelais 8 9 bei 41 981 aktiviert Das Schwachstromrelais bleibt aktiviert On solange Aktivit t registriert wird un...

Страница 12: ...de 1 min environ temps de d marrage Pour le raccordement du PIR et du poussoir voir les instructions relatives au Power Pack type 41 981 Lexique App Application indique la fonction du d tecteur Zones...

Страница 13: ...et aussi d teindre l clairage Le d tecteur de luminosit n a aucune fonction App Auto sans d tecteur de luminosit DIP 3 On DIP4 On Fig 6 7 Le d tecteur passe en test de bon fonctionnement pendant 5 min...

Страница 14: ...981 Le relais courant faible sera activ On tant que des mouvements seront d tect s et que la temporisation de d connexion 2 heures ne sera pas coul e LED On Off Allume et teint la DEL rouge indiquant...

Страница 15: ...ningen har kopplats in r r relsesensorn klar f r anv ndning efter cirka 1 minut uppv rmningstid Se bruksanvisningen f r Power Pack typ 41 981 om anslutning av PIR och knapp Ordlista App Applikation pr...

Страница 16: ...yckning Ljussensorn har ingen funktion App Manuell utan ljussensor DIP 3 On DIP4 On Fig 6 7 Sensorn f rs tts i ett g test under 5 minuter efter starten D refter sker f ljande Manuell t ndning via tryc...

Страница 17: ...er trycka p Lock unlock f rst N r Light 1 och 2 On Off aktiveras aktiveras ven svagstr msrel et 8 9 p 41 981 Svagstr msrel et r aktiverat On s l nge som aktivitet registreras och urkopplingstiden 2 ti...

Отзывы: