![SERVIS THG 46 VSS Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/servis/thg-46-vss/thg-46-vss_operating-and-installation-instructions_1246941014.webp)
Fig. 3.10
J
GAS CONVERSION
INJECTORS REPLACEMENT OF HOB BURNERS
The diameter is marked on the injector in cents of milimetre. Select the injectors to be
replaced according to the “Info chart supplied with the injector set”. To replace the
injectors:
• Remove pan-supports and burners from the cooktop.
•Using a spanner, remove the injector “J” (fig.3.10-3.11) from its housing and replace
it by the proper one according to the kind of gas (For correct injector sizes, refer to
the table on page 3).
12
• Failure to comply with this condition will render the guarantee invalid.
• The appliance must be installed in compliance with regulations in force.
• Installation engineers must comply to current laws in force concerning ventilation
and evacuation of exhaust gases.
• Always unplug the appliance before carrying out any maintenance or repairs.
• Minimum distance between the appliance and combustible premises must be 20
mm.
• After the connection had been it has to be tested.
• This test can be done by applying a soapy liquid to the connection. No bubble should
appear. If there are bubbles, check the connection joint and recheck it if necassary.
• For all gas connections, make sure that the connection parts and gas delivery
components are in accordance with local and international requirements.
DO NOT USE NAKED FLAME TO CHECK FOR GAS LEAKS