For additional protection the installation of a residual current device
(RCD) is recommended. ( Refer to local electrical regulations)
Remove all packaging material (including anti-vibration pads on the lamp) and check the
appliance, supply cord and the plug for signs of damage.
Pay attention to the mounting place and all mounting material. Ensure they are suitable
and stable enough for mounting and holding the appliance on your chosen surface.
Before mounting, the minimum safe mounting distances and tilt angles shown in the
figures must be strictly followed.
1.The distance between the bottom edge of the appliance and the floor must be at least 1.8 M.
2. There should be a distance of at least 0.2 M between the appliance and ceilings, roofs or other covers.
3. There should be a distance of at least 0.5 M at each side between the appliance and walls etc..
4 .Recommended degree to mounting surface is 45
°
.
See figure 2.
5. The max. swing degree is 90
°
Fix the mounting bracket on the wall first. Ensuring that the area of installation is
secure and firm.
Adjust the desired angle of radiation and tighten all screws. Check regularly as the
screws’ may loosen due to vibrations caused by wind or building
movement.
Plug or hard wire into your power source.
Check to ensure that the heater is working.
Figure 1:
Mounting bracket (wall bracket) and raw plugs
Figure 2:
Minimum distances to floor, ceiling and wall.
provided. Connection from the wall to the infrared heater.
45mm
45mm
45mm
0.2m
0.5m
1.8mm
Installation