INSTALLATION GUIDE FOR SERAPHIM 

DUAL GLASS PHOTOVOLTAIC MODULE

INSTALLATION GUIDE FOR SERAPHIM 

DUAL GLASS PHOTOVOLTAIC MODULE

Ta

ble 4

Loads(Pa) Screw Number

Installation Drawing

Installation Site

Outer four holes

Outer four holes

Inner four holes

Inner four holes

4

+ 2400

-  2400

+ 2400

-  2400

+ 5400

-  2400

+ 2400

-  2400

.

4

8

4

       +

Nextracker holes

6

&-&$53*$"-*/45"--"5*0/

WARNING Electrical Hazard 
This module produces electricity when exposed to light. Follow all appli-

cable electrical safety precautions.

• ONLY qualified personnel can install or perform maintenance work on these PV 
modules. 

• BE AWARE of dangerous high DC voltage when connecting module. 

• DO NOT damage or scratch the rear surface of the module.  

• DO NOT handle or install module when they are wet. 

The wiring components shall be compatible with the PV modules.

The PV modules connected in serial shall have similar current. The Voc of one PV 

string shall no higher than the maximum system voltage, the Voc temperature 
coefficient feature and the extreme low temperature of installation location must 

be taken into consideration when calculate the Voc of the PV string .

The PV modules connected in parallel shall have similar Voltage. The Isc tempera-
ture coefficient feature and the extreme high temperature of installation location 
must be taken into consideration when calculate the Isc of the PV array. 

Please refer to local regulations to determine the system wires size, type and tem-
perature. 

The cross-sectional area and cable connector capacity must satisfy the maximum 

short-circuit of PV system (For a single component, we recommended the 
cross-sectional area of cables is 4mm2 and the rated current of connectors is 

more than 15A), otherwise cables and connectors will become overheating for 

large current. Please pay attention: the temperature limit of cables is 85° C and the 
temperature limit of connector is 105°C 

A qualified system designer or integrator should always be consulted. 

Building permits, inspections and approvals by the local utility are generally 
required.

.&$)"/*$"-*/45"--"5*0/

&-&$53*$"-*/45"--"5*0/

12

13

Содержание SRP 6MA-BG Series

Страница 1: ...PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO LTD ADDRESS JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG ROAD NO 1 2 TELEPHONE 86 519 68788166 FAX 86 519 88786181 MAILBOX info seraphi...

Страница 2: ...lers should assume all risks of injury that might occur during installation including but not limited to the risk of electric shock One single PV module may generate more than 30V DC when exposed to d...

Страница 3: ...including wires and cables connectors charging regulators inverters storage batteries recharge able batteries etc Under normal outdoor conditions the current and voltage generated will differ from tho...

Страница 4: ...sunlight resources In the Northern Hemisphere the module should typically face south and in the Southern Hemisphere the modules should typically face north The most optimistic installation angle varie...

Страница 5: ...ithstand a downward force of up to 5400 Pa 550 kg m2 the modules shall be fixed on the bracket with the long side of the module using a minimum of four clamps Please make sure to use at least of two p...

Страница 6: ...xed on the bracket with the long side of the module using a minimum of four screws Please make sure to use at least of two purlins behind the modules to support the modules The selection and installat...

Страница 7: ...stem voltage the Voc temperature coefficient feature and the extreme low temperature of installation location must be taken into consideration when calculate the Voc of the PV string The PV modules co...

Страница 8: ...ny problem arises consult a professional for suggestions Caution observe the maintenance instructions for all components used in the system such as support frames charging regulators inverters batteri...

Страница 9: ...eet any of the following conditions 1 When the DC side input terminal of the inverter or combiner box is original MC4 2 When the manufacturer of inverter or combiner box requires series DC input bus t...

Отзывы: