TROUBLESHOOTING TIPS AND SUGGESTIONS
PUMP WILL NOT START OR CYCLEL:
■
Blocked liquid pipe or hose - Clean out or replace
■
Clogged liquid chamber - Remove debris
■
Diaphragm shaft bushing / o-ring leak - Replace o-rings
■
Air valve carrier not shifting - Inspect, clean
ERRATIC CYCLING:
■
Diaphragm failure - Replace diaphragm
■
Valve ball not seating properly, worn or damaged – Inspect, remove debris or replace
■
Leak in suction line - Inspect, repair or replace
■
Diaphragm shaft / o-ring leak - Replace o-rings
■
Air valve carrier not shifting - Inspect and clean
■
Over lubrication in air valve - Inspect, degrease, clean, and reuse. Remove lubrication
■
Excess moisture in air valve – Inspect, dry, reuse. Consider installing an air dryer
■
Worn carrier or valve bore – measure carrier and valve bore, diametrical clearance should be between 0,05 - 0,13 mm.
Replace worn components as needed
PUMP CYCLES BUT WILL NOT PUMP:
■
Too much suction lift - Reduce suction lift or try filling up liquid chambers with fluid
■
Leak in suction line - Inspect, repair or replace
■
Valve ball not seating properly, worn or damaged - Inspect, remove debris or replace
■
Clogged suction pipe or hose - Inspect & clear
■
Clogged strainer if used - Inspect & clear
■
Diaphragm failure - Replace diaphragm
PUMPED LIQUID RELEASED FROM AIR EXHAUST:
■
Diaphragm failure - Replace diaphragm
■
Outer plate unthreading - Tighten & re-torque