background image

SQ864

GPRS Terminal

15

Sales:  +44 (0) 118 967 9000 
Fax:  +44 (0) 118 976 9020

www.sequoia.co.uk

Rev 2.1.4 Jan 2011

Wireless Technology

Experience The Freedom

11.2 SIM card precautions

Before handling the SIM card in your application, ensure that you 
have discharged any static

electricity. Use standard precautions to avoid electrostatic 
discharges.

• 

 When designing the SQ864-GPRS into your application, 
the accessibility  of the SIM card should be taken into 
account so that it can be removed or changed.

• 

 We always recommend that you have the SIM card 
protected by a PIN code. This will ensure that the SIM 
card cannot be used by an unauthorized person.

11.3 Antenna precautions

If the antenna is to be mounted outside, always consider the risk of 
a lightning strike. Follow the instructions provided by the antenna 
manufacturer.

• 

 Never connect more than one terminal to a single 
antenna. The terminal can be damaged by radio 
frequency energy from the transmitter of another 
terminal.

• 

 With all mobile station equipment, the antenna of the 
terminal emits radio frequency energy. To avoid EMI 
(electromagnetic interference) you must determine if the 
application or equipment in the application’s proximity, 
needs further protection against radio emission and the 
disturbances it might cause. Protection is secured either 
by shielding the surrounding electronics or by moving the 
antenna away from the electronics and external signal 
cables.

• 

 The modem and antenna may be damaged if either 
come into contact with ground potentials other than 
the ground potential used in your application. Beware, 
ground potentials can vary significantly between 
hardware platforms.

12. Safety Recommendations

PLEASE READ CAREFULLY

Be sure the use of this product is allowed in the country and in the 
environment required. The use of

this product may be dangerous and has to be used with caution in 
the following areas:

• 

 Where it can interfere with other electronic devices in 
environments such as hospitals, airports, aircrafts, etc

• 

 Where there is risk of explosion such as gasoline stations, 
oil refineries, gas works etc

It is responsibility of the user to enforce the country regulation and 
the specific environment regulation.

Do not disassemble the product, any mark of tampering will 
compromise the warranty.

We recommend following the instructions of the hardware user 
guide for the correct wiring of the product. The product has to 
be supplied with a stabilized voltage source and the wiring has to 
conform to the security and fire prevention regulations.

The product has to be handled with care, avoid any direct contact 
with the pins because electrostatic discharge may damage the 
product. The same precautions have to be observed for the SIM 
card installation. Do not insert or remove the SIM when the 
product is in power

saving mode. (AT+CFUN=5)

The system integrator is responsible for the complete functionality 
of the final product. Therefore, care has to be taken with the 
external components used with the module, as well as any 
installation issue.

Should there be any doubt, please refer to the technical 
documentation and the regulations in force.Every module has to be 
equipped with a suitable antenna with characteristics which match 
the product requirements. 

Содержание SQ864

Страница 1: ...SQ864 GPRS Terminal Hardware reference manual Rev 2 1 4 Sales 44 0 118 967 9000 Fax 44 0 118 976 9020 www sequoia co uk...

Страница 2: ...232 5 6 SIM Socket 5 7 Antenna 5 7 1 Antenna Placement 5 7 1 Antenna Connection Cable 6 Power Consumption 7 Switching the SQ864 GPRS Terminal ON and OFF 8 Dimensions 8 1 Top View 8 2 Serial Connector...

Страница 3: ...976 9020 www sequoia co uk Rev 2 1 4 Jan 2011 Wireless Technology Experience The Freedom 3 Definitions Term Definition USB Universal Serial Bus VSWR Voltage Standing Wave Ratio SMA Sub Miniature versi...

Страница 4: ...ED Flash rate once per second Net search not registered turning off Slow rate once every 3 s Registered full service Constant ON Ringing OR call in progress OFF Module power down Green TGPIO_01 Reserv...

Страница 5: ...the power input are as follows Input voltage 5 to 16V DC Nominal input voltage 12V DC Supply current Peak 2A Average standby 25mA Call in progress 250mA Ringing 250mA The module is supplied with a 12...

Страница 6: ...cation as shown in table 5 PIN number Part number Function 1 0V Common 0V connection 2 RESET_IN External reset input 0V to 0 5V or open circuit inactive Reset OFF 2 to 16V active Reset ON must be acti...

Страница 7: ...trol of embedded application The following command has to be used to initialise and to set the digital output AT GPIO 5 1 1 switch output on AT GPIO 5 0 1 switch output off Mini USB Pin Signal on Teli...

Страница 8: ...IN4 Mini USB AT GPIO 12 2 0 read GPIO_12 PIN5 Mini USB 5 5 Digital Input A standard RS232 interface is provided through a 9 way D type socket All RS232 pins provide the following ESD protection 15kV H...

Страница 9: ...power The VSWR should be less than 3 1 to avoid damage to the device 5 7 1 Antenna placement When in service the antenna should be placed away from electronic devices or other antennas The recommende...

Страница 10: ...e a sharp signal transition from low to high to turn the modem on This transition should be a rising signal from 0V GND to VCC or at least a large fraction of that voltage range Very slow transitions...

Страница 11: ...000 Fax 44 0 118 976 9020 www sequoia co uk Rev 2 1 4 Jan 2011 Wireless Technology Experience The Freedom 8 Dimensions All dimensions are shown in mm The mounting holes are suitable for a M3 fixing sc...

Страница 12: ...4 GPRS Terminal 12 Sales 44 0 118 967 9000 Fax 44 0 118 976 9020 www sequoia co uk Rev 2 1 4 Jan 2011 Wireless Technology Experience The Freedom 8 3 Antenna and Power View 8 4 Sim and GPIO Indicator V...

Страница 13: ...signal strength by issuing the AT command AT CSQ See AT CSQ Signal Strength in the AT command manual Tip Before installing the modem you can use an ordinary mobile telephone to check the signal stren...

Страница 14: ...section 8 Terminal installation considerations before you begin your system integration 11 1 General precautions The SQ864 GPRS terminal is a standalone item designed for indoor use only For use outs...

Страница 15: ...r than the ground potential used in your application Beware ground potentials can vary significantly between hardware platforms 12 Safety Recommendations PLEASE READ CAREFULLY Be sure the use of this...

Страница 16: ...elecom installation instructions then no further evaluation is required under Article 3 2 of the R TTE Directive and no further involvement of a R TTE Directive Notified Body is required for the final...

Страница 17: ...010 Initial Draft MC 0 2 8 10 2010 Updated pin out and voltage levels MC 0 3 12 10 2010 Further updates RS 232 SIM socket and antenna MC 0 4 12 10 2010 Added power on truth table GPIO tolerance SIM pi...

Отзывы: