functionality of the meter, and will be avoid any warranty. 

 

Do not drop, or allow physical impact to the meter as there are high precision 

components inside that may break or render the meter measure accurately. 

 
 

Exclusion of liability 

We have checked the contents of this publication and every effort has been made to 
ensure that the descriptions are as accurate as possible. 

However, deviations from the description cannot be completely ruled out, so that no 
liability can be accepted for any errors or omissions contained in the information 

given. The data in this manual are checked regularly and the necessary corrections 
are included in subsequent editions. We are grateful for any improvements that you 
care to suggest. 

 

 

 

Copyright

 

Copyright (c) 2015 SEP EUROPE All rights Reserved.

 

It is prohibited to pass on or copy this document or to use or disclose its content 

without our express permission. Any duplication is a violation of the law and subject 
to criminal and civil penalties. All rights reserved, particularly in the event of a 
patent award or utility model registration. 

 

Registered trademarks 

SEP EUROPE is registered trademark of Schotman Elektro BV. 
 

 

 

 
1.2    Foreword 

 

Thank you for purchasing the SEP LEM012SD or LEM012SS DIN rail single phase 
two wire energy meter. The SEP LEM012SD and the LEM012SS energy meter is an 

advanced type electronic energy meter. With the SEP product range we have 
introduced a large scale of energy meters on the market suitable for 110VAC to 
400VAC (50 or 60Hz) 

 
Although we produce the SEP LEM012SD and the LEM012SS meter according to IEC 

62053-21 and our accurate quality inspection there might always be a possibility 
that your product shows a fault or failure for which we do apologize. Under normal 
conditions your product should give you years of benefit and pleasure. In case there 

is a problem with the energy meter you should contact your dealer immediately. All 
energy meters are sealed with a special seal. Once this seal is broken there is no 
possibility to claim (for) warranty. Therefore NEVER open an energy meter or break 

the seal of the energy meter. The warranty time is 12 months, after purchase, and 
only valid for construction faults. 

Содержание LEM012SD

Страница 1: ...METER 230V 5 40A 50Hz class 1 DIN rail single phase two wire energy meter 1 1 Safety instruction 1 2 Foreword 1 3 Performance criteria 1 4 Specifications 1 5 Intrinsic errors 1 6 Description 1 7 Dimen...

Страница 2: ...er may only be used for the application cases specified in the catalog and the user manual and only in connection with devices and components recommended and approved by SEP Europe Proper handling The...

Страница 3: ...alties All rights reserved particularly in the event of a patent award or utility model registration Registered trademarks SEP EUROPE is registered trademark of Schotman Elektro BV 1 2 Foreword Thank...

Страница 4: ...A 32A Over current withstand 960A for 0 01s Operational frequency range 50Hz 10 Internal power consumption 2W 10VA Test output flash rate Red LED 2000 pulses per kWh 0 5Wh imp Pulse output rate pins 2...

Страница 5: ...se PA inflammable retarding Terminal block PA inflammable retarding Protection cover PA inflammable retarding EN62053 21 Ui max 27V li max 27mA R DMMeteri ng Single phase 32A kWh meter R L 0 5 Wh imp...

Страница 6: ...switch or circuit breaker is near the meter The switch or circuit breaker should comply with the specifications of the building electrical design and all local regulations An external fuse or thermal...

Страница 7: ...er with apllicable Surge Protection Devices After finishing installation the meter must be sealed to prevent tampering Connection of the wires should be done in accordance with the underneath connecti...

Страница 8: ...onds the LCD display will show HELP 1 1 RA 0 5 Wh imp RL 0 5 Wh imp kWh 230V 5 32 A 50Hz 1 RA 0 5 Wh imp RL 0 5 Wh imp kWh 230V 5 32 A 50Hz c Meter version When the meter is switched on the power it w...

Страница 9: ...ower supplying the energy meter and the equipment to which it is installed before opening the protection cover to prevent the hazard of electric shock WARNING Maintenance or repair should be performed...

Страница 10: ...the spacing interval of running will be prolonged so that people is under the delusion that register can t run Contact a qualified technician When necessary replace the meter LCD backlight can t lit I...

Страница 11: ...nical support For questions about our products please contact SEP dealer in your in your region Your local SEP distributor Email mail sep europe nl www sep europe nl S E P Europe Weverstraat 4 9403 VJ...