SEP LEM012SD Скачать руководство пользователя страница 2

2                                                                                               

SEP LEMO12SD / LEM012SS 2015 

 

1.1 Safety instructions 

 

Information for Your Own Safety

 

                            This manual does not contain all of the safety measures for operation of the 

LEM012SD/LEM012SS, because special operating conditions, local code requirements 
or local, national or international regulations may necessary to take further measures. 
It does contain information which must be adhered to in the interests of your own 

personal safety and to avoid material damages.   

 

 
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                 

Warning 

Means that failure to observe the instruction can result in death, serious injury or 
considerable material damage. 
 

        Caution 

Means hazard of electric shock and failure to take the necessary safety precautions will 
result in death, serious injury or considerable material damage. 

 
 

 

Qualified personnel 

Commissioning and operation of the equipment (module, device) described in this 

manual may only be performed by qualified personnel. Qualified personnel in the   
sense of the safety information contained in this manual are persons who are 
authorized to commission, start up, ground and label devices, systems and circuits 

according to safety and regulatory standards. 

 

Use for the intended purpose 

The single phase energy meter may only be used for the application cases specified in 
the catalog and the user manual and only in connection with devices and components 

recommended and approved by SEP Europe. 

Proper handling 

The prerequisites for reliable operation of the product are proper transport, proper 
storage, installation and assembly, as well as proper operation and maintenance. 
When operating electrical equipment, certain parts of this equipment automatically 

carry dangerous voltages. Improper handling can therefore result in serious injury or 
material damage. 
 

 

Use only isolated tools. 

 

Do not connect while circuit is live (hot). 

 

Do not connect the meter to a 3 phase - 400VAC – network. 

 

Place the meter only in dry surroundings. 

 

Do not mount the meter in an explosive area or exposed to dust, mildew and 
insects.   

 

Make sure the used wires are suitable for the maximum current of this meter. 

 

Make sure the AC wires are connected correctly before activating the 

current/voltage to the meter. 

 

Do not touch the meter connecting clamps directly with your bare hands, with 
metal, blank wire or other material as you will have the chance of an electric shock 

and a possible chance for health damage. 

 

Make sure the protection cover is placed after installation. 

 

Installation, maintenance and repair should only be done by qualified personnel. 

 

Never break the seals and open the front cover as this might influence the 

 

 

Содержание LEM012SD

Страница 1: ...METER 230V 5 40A 50Hz class 1 DIN rail single phase two wire energy meter 1 1 Safety instruction 1 2 Foreword 1 3 Performance criteria 1 4 Specifications 1 5 Intrinsic errors 1 6 Description 1 7 Dimen...

Страница 2: ...er may only be used for the application cases specified in the catalog and the user manual and only in connection with devices and components recommended and approved by SEP Europe Proper handling The...

Страница 3: ...alties All rights reserved particularly in the event of a patent award or utility model registration Registered trademarks SEP EUROPE is registered trademark of Schotman Elektro BV 1 2 Foreword Thank...

Страница 4: ...A 32A Over current withstand 960A for 0 01s Operational frequency range 50Hz 10 Internal power consumption 2W 10VA Test output flash rate Red LED 2000 pulses per kWh 0 5Wh imp Pulse output rate pins 2...

Страница 5: ...se PA inflammable retarding Terminal block PA inflammable retarding Protection cover PA inflammable retarding EN62053 21 Ui max 27V li max 27mA R DMMeteri ng Single phase 32A kWh meter R L 0 5 Wh imp...

Страница 6: ...switch or circuit breaker is near the meter The switch or circuit breaker should comply with the specifications of the building electrical design and all local regulations An external fuse or thermal...

Страница 7: ...er with apllicable Surge Protection Devices After finishing installation the meter must be sealed to prevent tampering Connection of the wires should be done in accordance with the underneath connecti...

Страница 8: ...onds the LCD display will show HELP 1 1 RA 0 5 Wh imp RL 0 5 Wh imp kWh 230V 5 32 A 50Hz 1 RA 0 5 Wh imp RL 0 5 Wh imp kWh 230V 5 32 A 50Hz c Meter version When the meter is switched on the power it w...

Страница 9: ...ower supplying the energy meter and the equipment to which it is installed before opening the protection cover to prevent the hazard of electric shock WARNING Maintenance or repair should be performed...

Страница 10: ...the spacing interval of running will be prolonged so that people is under the delusion that register can t run Contact a qualified technician When necessary replace the meter LCD backlight can t lit I...

Страница 11: ...nical support For questions about our products please contact SEP dealer in your in your region Your local SEP distributor Email mail sep europe nl www sep europe nl S E P Europe Weverstraat 4 9403 VJ...

Отзывы: