F1-110 MANUAL VER 1.0.3
20
6. EVENT SETUP
6.1 SHOCK SENSOR SENSITIVITY
Setup the shock sensor sensitivity. (Range: off, 1 ~ 5)
- Default Value: 3 (5: Sensitivity High, 1 / Sensitivity Low)
- F1-110 on standby mode wakes up and starts to record by shock sensor sensitivity level 5.
6.2 ALARM INPUT:
Setup ALARM INPUT NO / NC / Off
Select 'NO' or ‘NC’ according to sensor type for ALARM EVENT RECORDING.
For Alarm Recording, user can setup up to 4 alarms.
6.2.1 Alarm Continue
Select between ‘Continue On’ and ‘Continue Off’. When selecting ‘on’, recording continues until
event stops regardless of post recording time.
6.3 ALARM OUTPUT
ALARM
INPUT
ALARM
OUTPUT
Normal Open
Normal Open
Alarm input type is Normal Open.
The device connected to alarm output is in
‘OFF ‘status and turns ON when events occur.
Normal Open
Normal Close
Alarm input type is Normal Open.
The device connected to alarm output is in ‘ON
‘status and turns OFF when events occur.
Normal Close
Normal Open
Alarm input type is Normal Close.
The device connected to alarm output is in
‘OFF ‘status and turns ON when events occur.
Normal Close
Normal Close
Alarm input type is Normal Close.
The device connected to alarm output is in ‘ON
‘status and turns OFF when events occur.
※
Alarm-Out is also activated when shock sensor is detected on standby status of parking mode.
6.4 SCHEDULE SETUP
Setup time for Schedule Recording (Up to 4 different time settings possible)
6.4.1 TIME: Start to record when scheduled time is up.
6.4.2 EVENT: to record when event (triggered by alarm-in device or shock sensor) occurs
during scheduled period.
※
Pre-recording time is 5 seconds. F1-110 starts to record 5 seconds before actual event time.