senva TotalSense Series Скачать руководство пользователя страница 9

Display Navigation Guide, TotalSense Series 

Page 9 of 19

 

154-0042-0B 

 

Air Quality Settings 

 

Parameter 

Description 

Selections 

Functionality 

Settings > 

Air Quality> 

Use Temp

 

Use 

Temperature in 

the Air Quality 

calculation 

Enabled 

These settings are used to enable or disable a 
sensor being used for the Air Quality calculation.  
For a sensor to be enabled it must be installed 
on the device.   
 
All sensors will be shipped with present elements 
enabled in the Air Quality calculation.

 

Disabled 

Settings > 

Air Quality> 

Use RH 

Use Humidity 

in the Air 

Quality 

calculation

 

Enabled

 

Disabled

 

Settings > 

Air Quality> 

Use CO2 

Use CO2 in the 

Air Quality 

calculation

 

Enabled

 

Disabled

 

Settings > 

Air Quality> 

Use PM 

Use PM in the 

Air Quality 

calculation

 

Enabled

 

Disabled

 

Settings > 

Air Quality> 

Use VOC 

Use VOC in the 

Air Quality 

calculation

 

Enabled

 

Disabled

 

Air Quality 

Settings >

  

Good-Fair

 

Adjust good-to-

fair threshold 

for air quality on 

display 

0-100  

(default: 70) 

When using the Air Quality setting in 

Display Settings

this value may be adjusted to change the threshold 
below which the display will show a “Fair” rating.  

Air Quality 

Settings >

 

Fair-Poor

 

Adjust fair-to-

poor threshold 

for air quality on 

display 

0-100  

(default: 40) 

When using the Air Quality setting in 

Display Settings

this value may be adjusted to change the threshold 
below which the display will show a “Poor” rating.  

Language 

Set the 

Language of the 

Air Quality 

display 

French 

When displaying the Air quality on the canter of the 
main screen, this will 

English 

(default) 

 

Содержание TotalSense Series

Страница 1: ...54 0042 0B Rev Release Date By Description of Change ECR 0A NAK Initial Release 0B 6 10 2022 NJS Updates for engineering CI release Copyright 2022 All rights reserved This document contains Senva Sens...

Страница 2: ...ttings 10 PM Settings 10 RH Settings 11 Temp Settings 11 TVOC Settings 12 Slider Settings 12 Relay Settings 13 PIR Settings 14 Advanced Settings Diagnostics 15 Advanced Settings 15 Diagnostics 15 Air...

Страница 3: ...he up and down arrows for 5 seconds to unlock Figure 1 Default Home Display Figure 2 Sample Display If you see a lock icon hold the up and down arrows for 5 seconds to unlock To change any setting pre...

Страница 4: ...set each digit individually and press enter to move cursor to the left When all digits are set the value will be saved when enter is pressed again To view comms navigate to view comms in the main men...

Страница 5: ...size in PM Settings Readings over 999 will be shown as mg m3 Slider Setpoint Value corresponding to position of slider set point will be displayed in center Slider range can be adjusted in Slider Set...

Страница 6: ...2 reading Current CO2 reading will be displayed in PPM Temp reading Current Temp reading will be displayed in either o F or o C See Temp Settings RH reading Current RH reading will be displayed in PM...

Страница 7: ...int as the baseline adjust this setpoint in Temp Settings PID CO2 Sets the output to a PID controller using the CO2 setpoint as the baseline adjust this setpoint in CO2 Settings PID Temp Set Point Set...

Страница 8: ...re decreases Settings Analog Output 1 PID KP Proportional Coefficient 0 100 default 0 Sets the Proportional gain PID Coefficient Settings Analog Output 1 PID Ki Integral Coefficient 0 100 default 0 Se...

Страница 9: ...isabled Settings Air Quality Use PM Use PM in the Air Quality calculation Enabled Disabled Settings Air Quality Use VOC Use VOC in the Air Quality calculation Enabled Disabled Air Quality Settings Goo...

Страница 10: ...Disable Enable ABC Enable default Disable default if dual channel CO2 is selected Enable or disable ABC function for CO2 sensor calibration It is not recommended to disable this unless you are using...

Страница 11: ...as PM selected as a source in Analog Parameters RH Settings Parameter Description Selections Functionality RH Settings Offset RH offset 5 to 5 default 0 Adjust RH reading by up to 5 RH Settings Analog...

Страница 12: ...5000 g m3 default 0 g m3 This value corresponds to the lowest point on an analog scale for a TVOC reading This will correspond to any analog output that has TVOC selected as a source Analog Parameter...

Страница 13: ...100 00 default depends on source selection Based on full scale range of the selected sensor set the value above which the relay will activate For example if CO2 is selected its full available range is...

Страница 14: ...when this time has expired AND the turn off threshold is met Relay Settings Min Off Min off time 1 240s default 3s When relay de activates it will not activate again until this time has lapsed regard...

Страница 15: ...sult factory 00000010 EEPROM data corruption Consult factory 00000100 EEPROM write error Consult factory 00001000 Device is currently using factory defaults Reset to factory defaults Consult factory 0...

Страница 16: ...is will display several possible statuses in binary All zeros indicate no errors or warnings are present 00000001 Sensor hardware I2C fault Consult factory 00000010 Sensor error bad initialization ran...

Страница 17: ...nsor Data Error Consult factory 00000100 Sensor not ready Consult factory 00001000 Sensor fan speed warning Warning only No action necessary 00010000 Sensor fan failure Consult factory 00100000 Sensor...

Страница 18: ...000 g m3 3000 g m3 CO2 1200 PPM 1200 2000 PPM 2000 PPM Temp 64 79F 64 79F RH 30 60 30 60 10 90 The average air quality is calculated as follows for the sensors that have been enabled see Air Quality s...

Страница 19: ...ale factor 1 218 Data Source http aqt vru com emissions complete list of vocs Contamination Name Molecular Weight Scale factor ACETYLENE ACETYLEN 26 04 0 565 FORMALDEHYDE FORMALD 30 03 0 652 METHANOL...

Отзывы: