12
5
Move the safe aside to clear both marked spots for drilling.
6
Drill into the floor:
A
For wood:
Using the
9
⁄
32
” drill bit, drill a hole 2
1
⁄
2
”
(64 mm) deep in each marked spot.
B
For masonry:
Using the
3
⁄
8
” drill bit, drill a hole 2
1
⁄
2
”
(64 mm) deep in each marked spot. Install a masonry
anchor in each hole.
7
Replace the safe in the desired position, with the holes in
the safe aligned with those in the floor.
8
Securing the safe:
A
For wood:
Pass each lag screw through a washer,
then through the safe and into a hole. Tighten with
the wrench.
B
For masonry:
Pass each lag screw through a washer,
then through the safe and into a masonry anchor.
Tighten with the wrench. Place masonry anchors into
the holes in the floor.
NOTE: •
The safe should not be bolted to a wall, this will compromise the fire rating.
Drill holes through the feet only. DO NOT drill through the back or sides.
•
Bolting/unbolting the unit is at the consumer’s expense and discretion.
•
SentrySafe is not responsible for any costs incurred if the unit is to be replaced.
Not all SentrySafe products come with a bolt-down kit.
Please go to
www.sentrysafe.com
to learn more about the recommended hardware for
your safe.
Bolting Down Your Safe
Bolt-down instructions… continued