General Description

The Sentry® Saf-T-Vise STV-HP1 and STV-HP3 insertable tool 

holders are multi-functional tools that can be equipped to 

monitor pipeline corrosion, inject chemical into the process, 

or sample the pipeline medium  The holders are engineered 

to specific site applications with a variety of materials and 

connection styles and sizes  Design pressure and temperature 

requirements determine the model series and sealing 

technology of the holder  

The holders are designed with a patented locking collet which 

secures the rod/shaft within the process stream until released 

by the operator  A process bleeder valve is standard on holders 

to allow depressurization of the holder after closure of the 

process isolation valve  The ability to fully retract the rod/shaft 

out of the pipeline while under pressure allows for pigging 

without bringing the line down 

The standard Saf-T-Vise STV-HP1 and STV-HP3 models require 

the use of an insertion tool 

Specifications

Saf-T-Vise STV-HP1 and STV-HP3 

Insertable Tool Holder Specifications

 

ƒ

Maximum allowable operating pressure (MAP) of 5,000 psi 

at 100°F (344 7 bar at 38°C) for the STV-HP1 and 7,500 psi 

at 100°F (517 1 bar at 38°C) for the STV-HP3  NOTE: Flanged units have a MAP based on the class of flange used for 

process line connection and can be rated to a lower MAP 

 

ƒ

The Teflon® seal has a process temperature range of 0°F to 450°F (-18°C to 232°C) 

 

ƒ

The graphoil seal has a process temperature range of 0°F to 1000°F (-18°C to 538°C) 

 

ƒ

Holder Type: Corrosion Coupon, Atomizer, Sample or Injection Quill 

 

ƒ

316/316L SS is the standard material for process wetted components 

 

ƒ

Connection Style: Flanged or NPT Threaded connection 

 

ƒ

Standard NPT Connection Sizes: 1/2", 3/4", 1", 1-1/2", or 2" 

 

ƒ

Flange Connection Sizes: Customer specified  (In flanged units, holder is threaded and welded to flange )

Installation and Operation

The Saf-T-Vise STV-HP1 and STV HP3 tool holders attach to a pipeline isolation valve by means of either a flanged or 

NPT threaded connection  A holder is installed or removed during the operation and maintenance of the equipment as 

detailed in the Saf-T-Vise STV-T Series Insertion Tools manual 

Upper body

assembly

Lower body

assembly

Upper body 

set screw

Bleeder 

valve

NPT pipeline

connection

Collet

lock bolt

Safety cap

Indicator 

button

Welded stop

Rod/shaft

Safety cap

NPT threads

Содержание Saf-T-Vise STV-HP1

Страница 1: ...Original Instructions Installation Operation Maintenance Manual Saf T Vise STV HP1 and STV HP3 Insertable Tool Holders S CM IOM 00506 3 03 22...

Страница 2: ...ability Sentry Equipment Corp its employees agents and the authors and contributors to this document specifically disclaim all liabilities and warranties express or implied including warranties of mer...

Страница 3: ...V HP3 Insertable Tool Holder Specifications 6 Installation and Operation 6 Maintenance 7 Inspecting the Safety Cap 7 Prepping the Tool Holder for Reinstallation 7 Cleaning the Rod Probe Shaft 7 Changi...

Страница 4: ...ons DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious inj...

Страница 5: ...ing with any chemical Read the product label and Material Safety Data Sheets MSDS carefully and follow the instructions exactly Potential Equipment Hazards Hot surfaces This equipment may have very ho...

Страница 6: ...wable operating pressure MAP of 5 000 psi at 100 F 344 7 bar at 38 C for the STV HP1 and 7 500 psi at 100 F 517 1 bar at 38 C for the STV HP3 NOTE Flanged units have a MAP based on the class of flange...

Страница 7: ...d anti seize lubricant to the holder threads Cleaning the Rod Probe Shaft The rod probe shaft should be cleaned each time the tool holder is removed from the line This helps prevent buildup on the rod...

Страница 8: ...arrow at the top of the shaft Use a medium crescent wrench to loosen the adapter lock nut Remove both the adapter and the lock nut Atomizer shaft or quill shaft With a permanent marker mark the rod t...

Страница 9: ...For Teflon seal Tighten the upper body until it is snug against the lower body Tighten set screw For graphoil seal Do not tighten the set screw until after installation of the rod shaft Thread but do...

Страница 10: ...mount of anti seize lubricant to the shaft end take special care not to get any anti seize lubricant in the shaft as this could clog your nozzle tip b Thread the fluid adapter onto the shaft and tight...

Страница 11: ...eaking from the top of the holder body where the rod shaft and body meet the graphoil seal is most likely loose 1 Adjust the top body to tighten the seal a Loosen the small set screw on the upper body...

Страница 12: ...ard the top of the holder and then reinstall the locking collet bolt 2 Check the collet for wear A worn collet will not distribute pressure evenly on the rod shaft and may cause damage If the collet i...

Страница 13: ...conditioning sampling and measuring gas liquid slurry powder solids steam or water within their production environments our customers obtain the critical insights they need to control and optimize the...

Страница 14: ...14 Sentry Equipment Corp This page is intentionally left blank...

Страница 15: ...Saf T Vise STV HP1 and STV HP3 15 This page is intentionally left blank...

Страница 16: ...sentry equip com 966 Blue Ribbon Circle North Oconomowoc WI 53066 U S A 1 262 567 7256 support sentry equip com Serving customers in more than 50 countries across six continents worldwide...

Отзывы: