Sentry Saf-T-Vise STV-HP1 Скачать руководство пользователя страница 5

Saf-T-Vise STV-HP1 and STV-HP3 5

General Safety Precautions

Product Selection, Installation, and Use

Improper selection, installation, or use can cause personal injury or property damage . It is solely the responsibility of users, 

through their own analysis and testing, to select products suitable for their specifi c application requirements, ensure they are 

properly maintained, and limit their use to their intended purpose .
Follow proper local, state, and federal regulations for proper installation and operational requirements .
Always use caution and common sense when working with any chemical . Read the product label and Material Safety Data 

Sheets (MSDS) carefully and follow the instructions exactly .

Potential Equipment Hazards

Hot surfaces!

 This equipment may have very hot surfaces . If an operator contacts a hot surface, injury may occur . Use 

protective clothing to prevent injury . If other equipment comes in contact with a hot surface, damage to the equipment may 

occur . Ensure the area around this equipment is kept clear to prevent damage from occurring .

High pressures!

 This equipment may contain fl uids at very high pressures . Prior to installing, removing or maintaining this 

equipment, ensure that the equipment is isolated from all connecting piping, the equipment is depressurized, the contents 

have been drained, and the equipment is cool .

Содержание Saf-T-Vise STV-HP1

Страница 1: ...Original Instructions Installation Operation Maintenance Manual Saf T Vise STV HP1 and STV HP3 Insertable Tool Holders S CM IOM 00506 3 03 22...

Страница 2: ...ability Sentry Equipment Corp its employees agents and the authors and contributors to this document specifically disclaim all liabilities and warranties express or implied including warranties of mer...

Страница 3: ...V HP3 Insertable Tool Holder Specifications 6 Installation and Operation 6 Maintenance 7 Inspecting the Safety Cap 7 Prepping the Tool Holder for Reinstallation 7 Cleaning the Rod Probe Shaft 7 Changi...

Страница 4: ...ons DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious inj...

Страница 5: ...ing with any chemical Read the product label and Material Safety Data Sheets MSDS carefully and follow the instructions exactly Potential Equipment Hazards Hot surfaces This equipment may have very ho...

Страница 6: ...wable operating pressure MAP of 5 000 psi at 100 F 344 7 bar at 38 C for the STV HP1 and 7 500 psi at 100 F 517 1 bar at 38 C for the STV HP3 NOTE Flanged units have a MAP based on the class of flange...

Страница 7: ...d anti seize lubricant to the holder threads Cleaning the Rod Probe Shaft The rod probe shaft should be cleaned each time the tool holder is removed from the line This helps prevent buildup on the rod...

Страница 8: ...arrow at the top of the shaft Use a medium crescent wrench to loosen the adapter lock nut Remove both the adapter and the lock nut Atomizer shaft or quill shaft With a permanent marker mark the rod t...

Страница 9: ...For Teflon seal Tighten the upper body until it is snug against the lower body Tighten set screw For graphoil seal Do not tighten the set screw until after installation of the rod shaft Thread but do...

Страница 10: ...mount of anti seize lubricant to the shaft end take special care not to get any anti seize lubricant in the shaft as this could clog your nozzle tip b Thread the fluid adapter onto the shaft and tight...

Страница 11: ...eaking from the top of the holder body where the rod shaft and body meet the graphoil seal is most likely loose 1 Adjust the top body to tighten the seal a Loosen the small set screw on the upper body...

Страница 12: ...ard the top of the holder and then reinstall the locking collet bolt 2 Check the collet for wear A worn collet will not distribute pressure evenly on the rod shaft and may cause damage If the collet i...

Страница 13: ...conditioning sampling and measuring gas liquid slurry powder solids steam or water within their production environments our customers obtain the critical insights they need to control and optimize the...

Страница 14: ...14 Sentry Equipment Corp This page is intentionally left blank...

Страница 15: ...Saf T Vise STV HP1 and STV HP3 15 This page is intentionally left blank...

Страница 16: ...sentry equip com 966 Blue Ribbon Circle North Oconomowoc WI 53066 U S A 1 262 567 7256 support sentry equip com Serving customers in more than 50 countries across six continents worldwide...

Отзывы: