Other errors
Cause/remedy
No function
Check supply line L1 and fuse
PS
.
Setpoint temperature is not reached
●
Bank sensor not activated in the technician menu (if available)
●
Sauna heater power too low/sauna room volume too large
●
Check supply and exhaust air
●
Check power consumption of U, V
and W
.
Coloured light continues to run even
though
the
control
unit
is
switched
off
Use
the
“All
Off”
function
to
turn
off
the
coloured
light.
Additional output cannot be dimmed
Activate dimming function in the technician menu (dimmable)
Operating
mode
switches
off
for no apparent reason
Check the setting of the runtime
Remote start does not respond
●
Control
unit
must be
in
operating
mode
“Standby
for
remote
control” (see “10.16.
Activating standby for
remote operatio
n” on
page 48)
●
Check the wiring of RS1 and RS2.
Time always starts at 00:00.
Battery discharged (see “Battery” on page 58)