5.7.
Safety shut-off
EN 60335-2-53 states that sauna controllers with a remote control function may
only be used for controlling a sauna heater which has satisfied the combustion
test in section 19.101. Alternatively, a suitable safety shut-off device can be
installed in or above the heater. This shuts the sauna heater off if items such as
a towel are placed on the sauna heater.
To install the safety shut-off device, perform the following steps:
1.
Install the safety shut-off device in accordance with the operating instructions
for the device.
2.
Feed the wires for the safety shut-off device through the cable gland
2
into
the low-voltage connection area.
3. Connect the wires for the temperature sensor to the terminals labelled “
OSG
”
in terminal strip
c
.
If a safety shut-off is not installed, a jumper must be fitted at the terminals
labelled “
OSG
”.
5.8. Auxiliary output
The additional output can, for example, be used for an infrared heater or infrared
heat plates.
1. Feed the connection cable for the additional device through the cable gland
9
into the connection area for 230 V/400 V.
2. Connect the power supply cables to terminal strip
g
in accordance with the
terminal diagram. Observe the operating instructions and safety instructions
for the respective device.
Please note the maximum connected load of the additional output:
●
Dimmable up to a maximum of 500 W
●
Switchable up to a maximum of 3500 W
5.9. Foil sensor (optional)
1. Feed the wires for the sensor through the cable gland
8
into the low-voltage
connection area on the expansion module.
2. Connect the sensor cables for the sensor to the terminals labelled
“
FOIL SENSOR
” in terminal strip
f
.