MIW-RDCV-EN-002 - 27 / 04 / 2017
12 - 17
Table 3 Manual mode - additional parameters
Parameter
Minimum
Maximum
Default value
Menu
Start output value (%)
0
100
20
Start output
Number of output steps
(7)
0
9
0
Steps
Start output step
(8)
0
9
0
Start step
Network settings
Net settings
ID
(9)
2
247
2
ID
(7)
When the number of output steps is set to:
0: There are no steps, the output is stepless from LO to HI
1: There are 2 steps (0 and 1) that correspond to the LO and HI settings
2: There are 3 steps (0, 1 and 2) that correspond to LO, halfway LO and HI, and HI
(8)
Only relevant when the number of steps > 0
(9)
In manual mode the Network ID can be adjusted. In automatic mode, the ID is always 2; the ID of the
connected sensor should be 1.
Table 4 Normal - Inverse function
Temperature sensor
Heat
Cool
Humidity sensor
Humidify
Dry
Air quality / CO
2
sensor
Obtain
Drain
RDCV
RESIDENTIAL HVAC
CONTROLLER