www.sentera.eu
MIW-DSMFX-2R-EN-000 - 05 / 07 / 2019
4 - 12
PRODUCT DESCRIPTION
The DSMFX-2R series are multifunctional duct transmitters which measure
temperature, relative humidity and CO
2
concentration level. Based on the
temperature and relative humidity measurements, the dew-point temperature is
calculated. The series features a wide range of low voltage power supply and three
analogue / modulating outputs. All parameters are accessible via Modbus RTU.
ARTICLE CODES
Code
Supply
Maximum
power con-
sumption
Nominal
power con-
sumption
Imax
DSMFG-2R
18—34 VDC
2,6 W
1,3 W
145 mA
DSMFF-2R
18—34 VDC / 15—24
VAC ±10 %
2,1 W (VAC) / 2,6
W (VDC)
1,3 W (VAC) /
1,48 W (VDC)
155 mA (VAC) /
145 mA (VDC)
INTENDED AREA OF USE
■
Monitoring duct temperature, relative humidity and CO
2
level in HVAC applications
TECHNICAL DATA
■
3 analogue / modulating outputs:
►
0—10 VDC mode: min. load 50 kΩ (R
L
≥ 50 kΩ)
►
0—20 mA: max. load 500 Ω (R
L
≤ 500 Ω)
►
PWM (open-collector type): PWM Frequency: 1 kHz, min. load 50 kΩ (R
L
≥ 50 kΩ);
PWM voltage level 3,3 VDC or 12 VDC
■
Selectable temperature range: -30—70 °C
■
Selectable relative humidity range: 0—100 %
■
Selectable CO
2
range: 0—2.000 ppm
■
Accuracy: ±0,4 °C (-30—70 °C); ±3 % rH (0—100% rH); ±30 ppm CO
2
(0—2.000 ppm CO
2
), depending on the selected parameter
■
Removable CO
2
NDIR sensor element
■
Minimum airflow velocity required: 1 m/s
■
Enclosure and probe material:
►
ASA, grey (RAL9002)
■
Protection standard: Enclosure: IP54, Probe: IP20
■
Operating ambient conditions:
►
temperature: -30—70 °C
►
rel. humidity: 0—100 % rH, (non-condensing)
■
Storage temperature: -10—60 °C
STANDARDS
■
EMC Directive 2014/30/EC:
►
EN 61326-1:2013 Electrical equipment for measurement, control and laboratory
use - EMC requirements - Part 1: General requirements
►
EN 61326-2-3:2013 Electrical equipment for measurement, control and
laboratory use - EMC requirements - Part 2-3: Particular requirements - Test
configuration, operational conditions and performance criteria for transducers
with integrated or remote signal conditioning
■
WEEE Directive 2012/19/EC
■
RoHs Directive 2011/65/EC
DSMFX-2R
MULTIFUNCTIONAL
DUCT TRANSMITTER