background image

                                                   

ST801B Optical Power Multi-Meter 

 

11 

n

 

Introduction for light source module 

1.  Open and close light source. 

If it is the first time to enter into the status of light source 

output 

state, 

it 

dose 

not 

output 

signal. 

And 

1310nm

,

1550nm

or 

Closing  the  light  source

  can  be 

chosen circularly by pressing 

“λ”

2. The modulation output of light source. 

When  any  wavelength  is  chosen,  press 

“▲”

  or 

“▼”

  to 

realize  the  modulation  selection  of  CW,  270Hz,  330Hz, 

1KHz, 2Khz, --AU auto wavelength identification. 

3. Display the working status information of stable light 

source 

The 

on  the  upper  left  of  the  LCD  is  blinking  all  the 

time  when  there  is  some  working  light  source.  And  it  is 

forbidden  to  look  at  the  output  end  of  laser  source  or  the 

connector of the optical fiber when the light source is under 

the  power  on  status.  The  LCD  displays  the  corresponding 

wavelength and modulation status when the tester is under 

the  module  of  stable  light  source.  When  it  is  back  to  the 

module of optical power, the LCD displays the information of 

optical  power,  as  well  as  the  corresponding  working  light 

source, it will indicate 1310nm or 1550nm on the upper side 

of 

Main display 1 

or 

Main display 3

. And it also shows the 

modulation frequency of the light source on the upper side 

of  LCD. When  the  light  source  is  under  the  modulation  of 

Auto

,  its  corresponding  working  light  source  (1310nm  or 

1550nm

will be blinking all the time.   

Содержание ST801B

Страница 1: ...ST801B Optical Power Multi Meter User Manual V1 0 Shandong Senter Electronic Co Ltd ...

Страница 2: ...ST801B Optical Power Multi Meter 2 Contents 1 Summary 3 2 Functions 4 3 Technical Specifications 5 4 Layout 7 5 Operations 9 6 Maintenance 12 7 Faults Solutions 13 ...

Страница 3: ...y advances the test efficiency The inner microprocessor and linearity magnification technology ensure the long time calibration and test accuracy Optical Power Multi meter can carry out not only the absolute and relative power test but also the optical loss test for fiber optical cable and optical passive devices automatically and it can save test results It can be widely used in LAN WLAN MAN CATV...

Страница 4: ...Hz and auto wavelength identification mode 2 8 Wavelength identification with the help of light modulation and identification mode 2 9 USB communication function can upload the test result to management software by USB port 2 10 Handheld large LCD display easy to operate 2 11 Real time clock function can real time display the current time provide recording time for data storage 2 12 Auto power off...

Страница 5: ...1dBm 6 Automatic frequency identification 330Hz 270Hz 1 KHz 2 KHz 7 Automatic wavelength identification with the help of corresponding modulation mode Optical source module 1 Emitter type FP LD DFB LD 2 Dual wavelength switch function 1310 20nm 1550 20nm 3 Spectral line width 5nm 4 Output optical power 7 dBm 0 dBm customized 5 Short time stability of output optical power 0 05dB 15min 6 Long time s...

Страница 6: ...itor inner battery voltage LCD display 3 Auto power off 10 minutes 4 1000 groups of test data storage and management 5 Battery 7 4V 1000mAh high performance rechargeable lithium battery or 4pcs AA dry battery 6 Working duration for battery 90h Li battery only optical power meter work 24h Li battery the optical source and optical power meter work synchronously 7 Operating temperature 10 40 8 Storag...

Страница 7: ...ST801B Optical Power Multi Meter 7 4 Layout ...

Страница 8: ...T801B Optical Power Multi Meter 8 LD Connector Light Source output interface When the light is turned on please don t look directly into optical output or connected fiber optic connectors in order not to ...

Страница 9: ...ster can open When the instrument is power on it defaults optical power meter module and 1310nm wavelength LCD shows the working wavelength optical power battery power modulation frequency identification and so on Pressing for over 3 seconds when tester is open the tester will shut down System defaults automatic power off in 10 minutes the LCD will show Auto OFF Open and close auto off function In...

Страница 10: ... 1550nm and 1625nm through this key The chosen wavelength will be displayed in LCD screen When the instrument is power on it defaults the wavelength of 1310nm and circulates in order of 1310nm 1490nm 1550nm 1625nm 850nm 1300nm 2 Show absolute power and relative power value The instrument defaults the absolute measurement of optical power The value displayed by main display 2 means logarithmic powe...

Страница 11: ...e time when there is some working light source And it is forbidden to look at the output end of laser source or the connector of the optical fiber when the light source is under the power on status The LCD displays the corresponding wavelength and modulation status when the tester is under the module of stable light source When it is back to the module of optical power the LCD displays the informa...

Страница 12: ...look directly at the optical output or the connected fiber optic connectors when the light turned on so as not to damage the eyes NOTE If you use batteries it is forbidden to charge the dry batteries to avoid danger To keep the performance of the instrument and prolong the service life please pay attention to the following 1 The instrument should be avoided to shock hit fall off and other mechanic...

Страница 13: ...he battery out if it is not used for long time to avoid the effect for battery life 7 Must use the charging adapter supported by the model of instrument 7 Faults Solutions Faults Reasons Solutions Cannot turn on the tester Low voltage of battery Charge the battery Big test error Sensor interface is dirty Clean the sensor interface Open light source but no optical power outputs Connector ceramic co...

Страница 14: ...T801B Optical Power Multi Meter Shandong Senter Electronic Co Ltd NO 98 WANJIE RD NEW HI TECH AREA ZIBO SHANDONG CHINA P C 255086 TEL 86 533 3589257 FAX 86 533 3589257 www senter cn export senter com cn ...

Отзывы: