ELECTRONIC CONTROL PANEL
EN - English
Page 8
Picture 7
POWER-UP
After power-up the display will show the installed software
version, f.e.:
After 5 seconds, it will automatically revert back to the service
mode.
POWER FAILURE
In the event of a power failure, the program will remain
stored in the NOVRAM® during an undefined period, while an
incorporated SuperCap (capacitor) will maintain the correct
time of day during a period of several hours; consequently, in
case of prolonged power failure, the time of day might not be
maintained; if this happens, the time of day will be reset to
8:00 when the power supply is re-established, while the
indication will flash, indicating that the time of day needs to
be set.
When the power failure occurs during the execution of an
automatic regeneration, the control valve will immediately
return to the service mode; when the power supply is re-
established, the control valve will stay in the service mode for
60 sec. and restart a complete regeneration from the
beginning.
TIMER FAILURE
In the event of a timer failure, the display will show the
message:
If powering off/on the water softener doesn’t solve this
problem, professional service is required.
SERVICE MODE
In service mode the display shows the time of day and the
remaining capacity:
REGENERATION MODE
In regeneration mode the display shows the total remaining
regeneration time and remaining cycle time:
The control valve can be reset to service mode at any time by
pressing the scroll
!
button, as such manually advancing it
through the regeneration cycles.
CHECKING THE FLOW METER
In case of water usage, the remaining capacity counter in the
service display will count back per unit, i.e. per litre. This way
the correct functioning of the water meter can be verified.
MANUAL REGENERATION
It is possible to manually initiate a regeneration.
1.
Press the scroll
y
button repeatedly until the display
shows:
·
If the control valve is left in this position, the
countdown timer will countdown to 0 sec and start a
regeneration.
·
To cancel this mode, press the scroll
y
button before
the countdown timer has reached 0 sec; the control
valve will return to the service mode.
2.
Press the scroll
y
button again if you want to manually
advance the control valve to the next regeneration cycle.
symbol
button
function
y
SCROLL
to advance to the next
parameter
z
UP
to increase the value of the
parameter
?
DOWN
to decrease the value of the
parameter
Service Required
E3DIR4d LGP2 r16
8:00 1000L -
Regen in 10 sec
20:51 1000L -
Rgn:XXX CycY:ZZZ