2.4 Environmental Specifications
Model Number
STC-MBS510U3V / STC-MCS510U3V
Operational
Temperature
Minimum
Environmental Temperature: 0 deg. ºC
Maximum
Camera housing temperature (top plate) shall not exceed 55 deg. ºC
(
*1
)
Storage Temperature
Environmental Temperature: -30 to +65 deg. C, Environmental
Humidity: 0 to 85%
Vibration
20Hz to 200Hz to 20Hz (5min./cycle), acceleration 10G, XYZ 3 directions 30 min. each
Shock
Acceleration 38G, half amplitude 6ms, XYZ 3 directions 3 times each
Standard Compliancy
EMS: EN61000-6-2, EMI: EN55011
RoHS
RoHS Compliant
Model Number
STC-MBS322U3V / STC-MCS322U3V
Operational
Temperature
Minimum
Environmental Temperature: 0 deg. ºC
Maximum
Camera housing temperature (top plate) shall not exceed 55 deg. ºC
(
*1
)
Storage Temperature
Environmental Temperature: -30 to +65 deg. C, Environmental
Humidity: 0 to 85%
Vibration
20Hz to 200Hz to 20Hz (5min./cycle), acceleration 10G, XYZ 3 directions 30 min. each
Shock
Acceleration 38G, half amplitude 6ms, XYZ 3 directions 3 times each
Standard Compliancy
EMS: EN61000-6-2, EMI: EN55011
RoHS
RoHS Compliant
*1: Please insure the camera is installed with the appropriate heat dissipation. If camera has a mounted lens and a tripod
with an aluminum plate, this could decrease the camera housing temperature for heat dissipation. When the internal
temperature sensor on the camera shows less than 65 ºC, the camera housing temperature (top plate) will be less than 55
ºC.
Upper side of camera
Measuring point