Sensor Technologies America, Inc.
1345 Valwood Parkway, Suite 320 :: Carrollton, Texas 75006
Phone: (972) 481-9223 :: Fax: (972) 481-9209 :: Toll Free: 1 (877) - SENTECH (736-8324)
www.SentechAmerica.com
12
STC-1100C & STC-1100D Series
Operating Manual
Rev. 0.2 - Updated September 26, 2005
II) Timing Chart
Note:
Trigger input pulse must be positive (STC-1100C) or negative (STC-1100D)
enabled.
b) “T”
- Integration period must be set within the following time length
Normal Speed Interlace:
100µmsec - 16.7msec
Normal Speed Progressive:
100µmsec - 16.7msec
Double Speed Progressive:
50µmsec - 8.3msec
c) “t1”
- From the rising edge of the trigger pulse to the vertical sync pulse
Normal Speed Interlace:
4H + Td
(19H with HD-synchronized trigger)
Normal Speed Progressive:
4H + Td
(5H with HD-synchronized trigger)
Double Speed Progressive:
4H + Td
(5H with HD-synchronized trigger)
d) “t2”
- From the rising edge of the trigger pulse to the video out
Normal Speed Interlace:
18H + Td
(19H with HD-synchronized trigger)
Normal Speed Progressive:
33H + Td
(34H with HD-synchronized trigger)
Double Speed Progressive:
33H + Td
(34H with HD-synchronized trigger)
e) Minimum trigger intervals are the following. Cycle speed of each trigger
must be greater than these values
Normal Speed Interlace:
18msec
Normal Speed Progressive:
36msec
Double Speed Progressive:
18msec