Enter the tube length, in feet, if the
tube length is greater than 100 feet.
If the tube is shorter than 100 feet,
leave the setting at the factory
default of 100. When the distance
has been entered, press the “ENT”
key to display the second sample
setup screen.
Unless specified otherwise, SenTech
Corporation
recommends
the
following alarm settings for all
refrigerants
except R-123
:
Low = 25 ppm
Main = 50 ppm
High = 500 ppm
Unless specified otherwise, SenTech
Corporation
recommends
the
following alarm settings for R-123:
Low = 25 ppm
Main = 50 ppm
High = 150 ppm
These settings are based on the
current acceptable exposure levels
and short-term exposure levels on a
time
weighted
average
for
refrigerants. SenTech recommends
that under no circumstances should
a refrigerant monitor be set above
the
short-term
exposure
level.
These are recommended settings
only. Refer to local codes and
regulations
for
the
appropriate
settings for a given application.
Once the gas code, distance and
alarm settings have been entered,
press the “ABORT” key to return to
the Setup Menu.
If any of the available sample ports
are not used, press the “2” key to
enter the enable/disable screen.
Press the left or right arrow keys to
change from one sample area
screen to another. Press the “ENT”
key to move the arrow cursor from
line one to line two.
To bypass, or disable a sample area,
change the “1” to a “0” and press the
“ENT” key. Once the appropriate
areas have been disabled, press the
“ABORT” key to return to the IR-
Setup screen, again to return to the
Setup Screen, and again to return to
normal
operation.
The
monitor
should enter Auto zero mode.
Alarm Low 25 -
Alarm Main 50
Alarm High 500
ENT or ABORT
AREA 1
R-134A 8
Distance 250 -
ENT or ABORT
Program Setpoints
For Each AREA
1 – Setup
2 – Enable ABORT
AREA 1 <- ->
Status 1
1-Enable 0-Bypass
ENT or ABORT