FlexPI Product Guide
Page 43
b
Specifications
Processor
Model
•
processor card and indoor enclosure
PCB dimensions (L x W)
•
12 x 9 cm (4.7 x 3.5 in.)
Quantity
•
one per sensor zone
Probability of detection
•
greater than 95% with a 95% confidence factor
Maximum Zone length
•
600 m (1970 ft.)
Power consumption
•
1 W maximum
Power input
•
12 to 48 VDC
Connectors
•
removable terminal block for power input
•
removable terminal block for relay output connections
•
removable terminal block for sensor cable input
•
USB port for UCM connection
Controls
•
calibration adjustments via the Universal Configuration Module
(software application)
•
calibration adjustments via onboard switches
•
adjustable filter settings - frequency response
Alarm outputs
•
2 form C relays rated 30 VDC @ 1 A max. non-inductive load
•
1 ALARM relay - activates to signal sensor alarm condition
•
1 SUPERVISION relay - activates to signal enclosure tamper
condition, cable fault condition, processor fault condition
•
1 normally open SONALERT alarm output rated 30 VDC @ 1 A max.
for remote alarm annunciation (follows the state of the ALARM relay)
•
1 user-selectable onboard audible alarm (beeper) - follows the state
of the ALARM relay; beeps to signal sensor alarm - SW5-3 ON
enables beeper; SW5-3 OFF disables beeper