Item
Description
Item
Description
1
S1 - CLIMB switch - Sets the minimum time of
a sustained attack that must accumulate
before an alarm is declared (0.5 to 7.5
seconds).
6
RESPONSE LEVEL - Bar LED graph
indicates the received signal strength from
the sensor cable.
1a
CLIMB LEDs - 4 LEDs correspond to 4 Climb
switches, LED ON = switch ON.
7
Activity LEDs indicate Power, Supervision
condition, Sensor Alarm, UCM, Door.
2
S2 - TIME WINDOW switch - Sets the time
period during which the specified number of
impacts must occur; OR the period in which
the sustained attack time must accumulate
before an alarm is declared (8 to 128
seconds).
8
T1 - USB connection to UCM PC.
2a
TIME WINDOW LEDs - 4 LEDs correspond to
4 TIME WINDOW switches, LED ON = switch
ON.
9
T5 - RELAY CONNECTIONS -
Supervision (P1 - P3); Sonalert (P4 & P5);
Alarm (P6 - P8); T5 - POWER INPUT,
12 to 48 VDC, (P9
-
VDC, P10 +VDC
3
S3 CUT switch - Sets the number of discrete
impacts which must occur within a specified
time period for an alarm to be declared
(1 to 15 impacts within 8 to 128 seconds).
10
Cable entry port compression glands (power
cable, alarm data cable, sensor cable).
3a
CUT LEDs - 4 LEDs correspond to 4 Cut
switches, LED ON = switch ON.
11
PCB mounting screws (X 4).
4
S4 GAIN/THRESHOLD switch - Sets the input
signal amplification before the signal is
processed - 4 settings from 1 (low) to 4 (high)
12
Enclosure cover mounting holes (X4).
4a
GAIN/THRESHOLD LEDs - 4 LEDs
correspond to 4 Gain settings, LED ON =
switch ON.
13
T4 - SENSOR CABLE connection (GND/
SHIELD - connect twisted braided shield;
FLEX IN/CENTER - connect center
conductor).
5
S5 MISC switch (miscellaneous controls)
S5-1 sets the frequency band filter response
(OFF = high band 300 to 900 Hz;
ON = low band 100 to 300 Hz)
S5-2 sets the RESPONSE LEVEL bar LED
graph mode (OFF = envelope mode; ON =
peak mode) Envelope mode shows an
averaged signal response for an impact; Peak
mode shows the peak signal response for an
impact
S5-3 controls the onboard audio alarm
(OFF = audio alarm disabled; ON = audio
alarm enabled).
S5-4 sets the processor calibration mode
(OFF = UCM calibration; ON = onboard switch
calibration).
14
T6 - LOCAL TERMINATION header, provides
onboard cable termination for troubleshooting
- remove the shunt if a properly terminated
sensor cable is connected to the processor.
15
Enclosure cover tamper switch and tamper
switch lever.
(When the tamper switch is closed, the
onboard LEDs are OFF to conserve power.)
5a
MISC LEDs - 4 LEDs correspond to 4 MISC
switches, LED ON = switch ON
16
T3 - Tamper switch bypass header. Installing
a shunt on T3 disables the enclosure tamper
circuit.
Note that an enclosure tamper condition must
exist for the UCM to connect to the processor.
Table 1 Processor features