Conquest
7-Examples & Interpretation
35
Case #3
In Figure 7-3a) we see wire mesh again, with two conduits running at oblique angles to and
directly beneath the mesh. Figure 7-3b) shows the bottom of concrete between 9.6 to 10.8
inches deep. In this case, it is slab on pan which is a metal support sheet on which concrete was
poured during construction. The radar waves can not penetrate metal, and hence, the signals are
reflected entirely.