background image

10 

Entering the quick-access menu is executed in the operation mode by long pressing 

(more than 1 second) the right button. The 

USEr

 menu designation and the first menu item 

SEt.u

 shall appear on the screen. 

Exit from the quick-access menu shall be performed if:  

-

  both buttons are pressed simultaneously; 

-

 

End

 menu item is reached; 

-

  None of the buttons were pressed for at least 2 minutes. 

Menu usually includes two chapters: 

SEt.u 

menu item contains user settings menu, i.e. Contains sub-items, correspond-

ing to initial data or measured parameters. Menu item 

SEt.u

 enables quick data changing 

of  initial  data  and  parameters  during  display  either  in  measuring  or  emulation  mode.  Dis-
played content of 

SEt.u 

menu item depends on transducer type. 

Hold

 

– parameters viewing in hold mode. Provides a possibility to hold and view the 

last  changes  for  transducer,  including  those  which  are  not  set  for  displaying  in  operation 
mode for current transducer.  

Please follow the Operation Manual for the certain device and cl. 2.4. Of the present 

Operation Manual. 

2.4.2 Settings of signal device: 

2.4.2.1. General information 

Signal  device  adjustment  is  executed  via  the  adjustment  menu  (see  picture  2.10). 

Configuration of transducer is completely carried out by the Manufacturer according to the 
purchase  order  data.  The  reconfiguration  of  the  signal  device  during  operation  may  be 
needed if the purchase order data was incomplete or mismatching. 

Signal device in configuration mode does not affect functionality of other devices in 

the line; at the same time, it neither interrogates transducer, nor reacts on reaching of criti-
cal level. 

Signal device control is executed with the buttons placed on the signal device front 

panel;  the  certain  data  shall  be  displayed  on  the  signal  device  screen.  During  operation, 
short-press (duration less than 1 second) and long-press of buttons are distinguished. 

In  operation  mode  during  viewing  of  parameters,  transition  from  one  parameter  to 

another  is  performed  by  short-press  of  right-button  of  the  signal  device,  and  transition  to 
viewing  of  parameters  of  the  next  device  is  performed  by  short-  or  long-  press  of  the  left 
button. 

Menu scrolling is performed as follows: 
Current menu item is shown on the signal device display. Moving to next or previous 

menu item is performed by short-press of right or left button respectively. Selection of cur-
rent menu item (enter) is performed by short-press of the right button.  

Location field

Menu item 

designation

Caption

Main field

Device type or

menu item 

Device name and its

address in 

«SENS» line

Information field

Main configurable 

SEnS

SEtt

PMP-118
Address: 002

Viewing menu

 

Picture 2.6. 

Содержание SENS MS-K-500-3

Страница 1: ...Research and production enterprise SENSOR SENS device Signaling device MS K 500 3 MS K 500 3S Operation Manual ...

Страница 2: ... Technical specifications 3 1 3 Completeness 3 1 4 Design and operation 4 1 5 Marking 6 2 1 Safety measures notification 6 2 2 Operational limitations 6 2 4 Used items 8 3 MAINTENANCE 16 4 ROUTINE PRODUCT REPAIR 17 5 TRANSPORTATION AND STORAGE 17 6 UTILIZING 17 7 ANNEX A 18 ...

Страница 3: ...he range from minus 5 up to 50 C or S3 as per GOST R 52931 2008 1 2 Technical specifications 1 2 1 Mechanical impact resistance of MS K 500 3 and MS K 500 3C signal device corresponds to V1 as per GOST R 52931 1 2 2 Water and dust ingress protection degree of the signal device is IP54 accord ing to 1 2 3 Normal functioning of the signal device can be provided if the length of power and communicati...

Страница 4: ...llowing devices are installed under the signal device cover Record protection toggle 10 piezoelectric ring 6 and terminal clamp 8 designed for external circuits connec tion 1 housing 2 cover 3 cable fitting 4 looking glass 5 exterior panels 6 piezoelectric ring 7 control button 8 terminal clamp 9 installation orifice 10 record protection toggle 11 silicone gasket 12 protective sealing orifice 13 n...

Страница 5: ...signal device is config ured on reaction for certain events occurrence then if the event occurred certain status byte received the indicator displays the device address designation and value of the pa rameter the indication is glowing In accordance with operator s actions the signal device in operation mode interro gates the devices connected to a SENS line and displays the parameters set by the o...

Страница 6: ...f BK shall be only performed with power supply disconnected 2 2 Operational limitations 2 2 1 Use of a signaling device with mismatching power supply voltage is not al lowed 2 2 2 List of critical failures of signaling devices is given in table 2 1 Table 2 1 Failure Cause Actions A device is not op erable Mismatching power sup ply voltage Check and bring into accordance Power and or control circui...

Страница 7: ...k For operation check it is required to supply power on a signal device within 1 5 se conds signal device should emit one short sound signal Then signal device shall be switched to an operation mode or a sleep mode the flashing dot or a last interrogated sensor address shall appear on the screen In case of sound signal missing or wrong indi cation on the screen signal device should be deemed as ma...

Страница 8: ...king 9 2 3 5 After wiring it is required to configure signal device in accordance with a spe cific application It is necessary to check the accordance of settings recorded in configura tion data sheet for specific application and if necessary adjust the configuration Configu ration is made in accordance with cl 2 4 2 All changes must be recorded in configuration data sheet 2 3 6 Check operational ...

Страница 9: ...pressure Picture 2 3 Scrolling from one parameter to the other is executed by short pressing of the signal device right button Scrolling to next device parameter view is executed by long pressing or short pressing of the right button of signal device picture 2 4 Long press inscrease value Short press select parameter back left Long press decrease value Both buttons 1 go to settings mode 2 back und...

Страница 10: ...y carried out by the Manufacturer according to the purchase order data The reconfiguration of the signal device during operation may be needed if the purchase order data was incomplete or mismatching Signal device in configuration mode does not affect functionality of other devices in the line at the same time it neither interrogates transducer nor reacts on reaching of criti cal level Signal devi...

Страница 11: ...o exit without saving changes indica tor boards will show message no no saving End Any changes Err S SAV Back to menu Not saved Yes No Save No changes no Not saved cancelled Er tr Device not responding YES Save Saved t Wait Picture 2 7 If the saving reading calibration etc operations requires more than 1 second the screen will display t in the main field and Wait in the information field picture 2...

Страница 12: ...t d1 1 200м ПМП 201А Адрес 002 Глубина погружения SEtt d1 1 200м ПМП 201А Адрес 002 Отступ от дна резерв SEtt d0 9 200м ПМП 201А Адрес 002 Отступ от дна резерв SEtt d0 9 200м ПМП 201А Адрес 002 Глубина погружения SEtt d1 1 200м ПМП 201А Адрес 002 Глубина погружения SEtt d1 1 200м ПМП 201А Адрес 002 Глубина погружения SEtt d1 1 200м ПМП 201А Адрес 002 Глубина погружения SEtt d1 1 200м ПМП 201А Адре...

Страница 13: ...peration mode End End Br Picture 2 11 List of items sub items and configuration menu parameters is listed in table 8 3 Table 2 3 N o Item sub item parameter Note Desig nation Name Des ignati on Name unit of measure ment 1 SEE Not used 2 SEtt Main configurable parameters F Interrogation period s Set in accordance with 2 4 4 3 3 Br Indicator brightness 4 S SEE Table of devices set for viewing 1 n Se...

Страница 14: ...or brightness adjustment Brightness value ranges from 0 to 100 The more the Br value the more the bright ness It is recommended to set the middle brightness level value because the operation within the highest brightness values shall reduce the lifetime of OLED screen 2 4 4 2 Configuration table of viewed devices S SEE menu sub item provides adjustment of parameters set for viewing in opera tion m...

Страница 15: ...t will be flashing Set the required reaction short line event is ignored long line reaction is set Scroll to End item and exit with saving changes To delete devices from table it is required to perform the following actions Choose the record subjected for removal Change the device address to 00 Scroll to End item and exit with saving changes Notes 1 Device addresses are sorted automatically by inc...

Страница 16: ...interrogated by other signal device in the same time Warning If 0 address is used for configuration only one device can be con nected to the signaling device otherwise other devices can be reprogrammed by accident this can affect address and other settings i e only two devices with ad dress shall be in the line the signaling device and a device with unknown address 2 4 4 INDICATION OF ERRORS In ca...

Страница 17: ...depending on operating conditions 4 ROUTINE PRODUCT REPAIR 4 1 Product repair is replacement of broken parts and units it can be carried out by organization granted to do repair of explosion proof equipment Spare parts are supplied by the manufacturer 5 TRANSPORTATION AND STORAGE 5 1 Transportation conditions shall correspond to GOST 15150 69 at medium tem perature range from 50 C to 50 C Transpor...

Страница 18: ...ation conditions as to environment climatic as pects influence 1 1 2 5 1 5 2 GOST 30852 13 2002 IEC 60079 14 1996 Explosion proof electrical apparatus Part 14 Electrical installations in explosive gas atmos pheres other than mines 2 1 2 GOST 30852 16 2002 IEC 60079 17 1996 Explosion proof electrical apparatus Part 17 Inspection and maintenance of electrical installa tions in hazardous areas other ...

Страница 19: ...19 NPP SENSOR LLC RUSSIA 442965 Zarechny Penza region P O Box 737 phone fax 7 841 2 65 21 00 7 841 2 65 21 55 Corr 21 10 2019 ...

Отзывы: