10
Entering the quick-access menu is executed in the operation mode by long pressing
(more than 1 second) the right button. The
USEr
menu designation and the first menu item
SEt.u
shall appear on the screen.
Exit from the quick-access menu shall be performed if:
-
both buttons are pressed simultaneously;
-
End
menu item is reached;
-
None of the buttons were pressed for at least 2 minutes.
Menu usually includes two chapters:
SEt.u
menu item contains user settings menu, i.e. Contains sub-items, correspond-
ing to initial data or measured parameters. Menu item
SEt.u
enables quick data changing
of initial data and parameters during display either in measuring or emulation mode. Dis-
played content of
SEt.u
menu item depends on transducer type.
Hold
– parameters viewing in hold mode. Provides a possibility to hold and view the
last changes for transducer, including those which are not set for displaying in operation
mode for current transducer.
Please follow the Operation Manual for the certain device and cl. 2.4. Of the present
Operation Manual.
2.4.2 Settings of signal device:
2.4.2.1. General information
Signal device adjustment is executed via the adjustment menu (see picture 2.10).
Configuration of transducer is completely carried out by the Manufacturer according to the
purchase order data. The reconfiguration of the signal device during operation may be
needed if the purchase order data was incomplete or mismatching.
Signal device in configuration mode does not affect functionality of other devices in
the line; at the same time, it neither interrogates transducer, nor reacts on reaching of criti-
cal level.
Signal device control is executed with the buttons placed on the signal device front
panel; the certain data shall be displayed on the signal device screen. During operation,
short-press (duration less than 1 second) and long-press of buttons are distinguished.
In operation mode during viewing of parameters, transition from one parameter to
another is performed by short-press of right-button of the signal device, and transition to
viewing of parameters of the next device is performed by short- or long- press of the left
button.
Menu scrolling is performed as follows:
Current menu item is shown on the signal device display. Moving to next or previous
menu item is performed by short-press of right or left button respectively. Selection of cur-
rent menu item (enter) is performed by short-press of the right button.
Location field
Menu item
designation
Caption
Main field
Device type or
menu item
Device name and its
address in
«SENS» line
Information field
Main configurable
SEnS
SEtt
PMP-118
Address: 002
Viewing menu
Picture 2.6.