Instantaneous Mode enables displaying and logging results with frequency 8 times for the second.
In order to choose the Instantaneous Mode one should press the ‘ INST ’ button and then the
‘Instantaneous Measurement’ front panel appears. The user can select probe for observation the
temperature and the speed in the real time on charts on the right side of panel. On the left side there is
the chart with a logged speed. The number of probe for logging is selected independently in the control
' Logged probe select ' below the chart. On the panel is also a table with the current results for all of the
probes.
Logging time is selected in the control ' Logging Time '. After pressing the ' START ' button shows a
window ' Select file for data logging ', in which the user should enter a file name for the logging and the
logging procedure starts. Interrupting the logging in every moment is possible, after pressing the ‘
STOP ’ button.
Remarks:
1.
Don’t use more than two SensoBee wire-less transmitters in case of use wire-less communication.
2.
For configuration with more than five SensoAnemo transducers the instantaneous results are shown
on the charts with delayed 1s.
D
D
a
a
t
t
a
a
S
S
o
o
c
c
k
k
e
e
t
t
C
C
o
o
n
n
n
n
e
e
c
c
t
t
i
i
o
o
n
n
When you use this protocol, the program communicates with the DataSocket Server. You must provide a
named tag for the data, which is appended to the URL. The data connection uses the named tag to address
a particular data item on a DataSocket Server. To use this protocol, you must run a DataSocket Server.
In order to enable or disable the DataSocket connection, select ‘DataSocket’ from the menu item ‘Data
Communication…’ on the menu bar on front panel.
You publish (write) data by specifying a URL. You should enter 'localhost' on the publisher computer and
IP address of the publisher on the subscriber computer.
The example of Data Socket Reader is available in the Program Menu Folder (SENSOR
Electronic\Examples).
16
16
1
=
=
i
i
t
t
16
16
1
=
=
i
i
v
v
16
16
1
2
=
=
i
i
v
v
Results calculated
in a transducers
Results calculated
in a computer
N
t
t
N
j
j
m
=
=
1
N
v
v
N
j
j
m
=
=
1
2
1
2
m
N
j
j
v
N
v
SD
-
=
=
i
t
– instantaneous temperature
i
v
– instantaneous speed
t
– two second average value of temperature
v
– two second average value of speed
v
– root of two second average value of square speed
m
t
– average temperature in any averaging time
m
v
– average speed in any averaging time
SD
– standard deviation of speed in any averaging time
s
T
N
a
2
=
where
a
T
is averaging time
Sent to a computer
every 2s
t
v
v