MT3896E Rev.1 

15/10/2019 

Pagina 20 di 45 

 

Example

 

Se  i  due 

commutatori  sono  posizionati  come  sopra,  RSW2  su  0  ed  RSW1  su  D,  l’indirizzo 

corrispondente in decimale è 13 (vedi tabella 1) 
If the address switches are set in this manner, RSW2 at 0 and RSW1 at D, the corresponding address in 
decimal number would be 13 (see table 1). 

 

 

Tabella1: Conversione da decimale ad esadecimale  
Table 

1

: Conversion from decimal to hexadecimal numbers 

 

DEC 

HEX 

DEC 

HEX 

DEC 

HEX 

DEC 

HEX 

DEC 

HEX 

DEC 

HEX 

DEC 

HEX 

01 

38 

26 

75 

4B 

112 

70 

149 

95 

186 

BA 

223 

DF 

02 

39 

27 

76 

4C 

113 

71 

150 

96 

187 

BB 

224 

E0 

03 

40 

28 

77 

4D 

114 

72 

151 

97 

188 

BC 

225 

E1 

04 

41 

29 

78 

4E 

115 

73 

152 

98 

189 

BD 

226 

E2 

05 

42 

2A 

79 

4F 

116 

74 

153 

99 

190 

BE 

227 

E3 

06 

43 

2B 

80 

50 

117 

75 

154 

9A 

191 

BF 

228 

E4 

07 

44 

2C 

81 

51 

118 

76 

155 

9B 

192 

C0 

229 

E5 

08 

45 

2D 

82 

52 

119 

77 

156 

9C 

193 

C1 

230 

E6 

09 

46 

2E 

83 

53 

120 

78 

157 

9D 

194 

C2 

231 

E7 

10 

0A 

47 

2F 

84 

54 

121 

79 

158 

9E 

195 

C3 

232 

E8 

11 

0B 

48 

30 

85 

55 

122 

7A 

159 

9F 

196 

C4 

233 

E9 

12 

0C 

49 

31 

86 

56 

123 

7B 

160 

A0 

197 

C5 

234 

EA 

13 

0D 

50 

32 

87 

57 

124 

7C 

161 

A1 

198 

C6 

235 

EB 

14 

0E 

51 

33 

88 

58 

125 

7D 

162 

A2 

199 

C7 

236 

EC 

15 

0F 

52 

34 

89 

59 

126 

7E 

163 

A3 

200 

C8 

237 

ED 

16 

10 

53 

35 

90 

5A 

127 

7F 

164 

A4 

201 

C9 

238 

EE 

17 

11 

54 

36 

91 

5B 

128 

80 

165 

A5 

202 

CA 

239 

EF 

18 

12 

55 

37 

92 

5C 

129 

81 

166 

A6 

203 

CB 

240 

F0 

19 

13 

56 

38 

93 

5D 

130 

82 

167 

A7 

204 

CC 

241 

F1 

20 

14 

57 

39 

94 

5E 

131 

83 

168 

A8 

205 

CD 

242 

F2 

21 

15 

58 

3A 

95 

5F 

132 

84 

169 

A9 

206 

CE 

243 

F3 

22 

16 

59 

3B 

96 

60 

133 

85 

170 

AA 

207 

CF 

244 

F4 

23 

17 

60 

3C 

97 

61 

134 

86 

171 

AB 

208 

D0 

245 

F5 

24 

18 

61 

3D 

98 

62 

135 

87 

172 

AC 

209 

D1 

246 

F6 

25 

19 

62 

3E 

99 

63 

136 

88 

173 

AD 

210 

D2 

247 

F7 

26 

1A 

63 

3F 

100 

64 

137 

89 

174 

AE 

211 

D3 

248 (*) 

F8 

27 

1B 

64 

40 

101 

65 

138 

8A 

175 

AF 

212 

D4 

249 (*) 

F9 

28 

1C 

65 

41 

102 

66 

139 

8B 

176 

B0 

213 

D5 

250 (*) 

FA 

29 

1D 

66 

42 

103 

67 

140 

8C 

177 

B1 

214 

D6 

251 (*) 

FB 

30 

1E 

67 

43 

104 

68 

141 

8D 

178 

B2 

215 

D7 

252 (*) 

FC 

31 

1F 

68 

44 

105 

69 

142 

8E 

179 

B3 

216 

D8 

253 (*) 

FD 

32 

20 

69 

45 

106 

6A 

143 

8F 

180 

B4 

217 

D9 

254 (*) 

FE 

33 

21 

70 

46 

107 

6B 

144 

90 

181 

B5 

218 

DA 

255 

(**) 

FF 

34 

22 

71 

47 

108 

6C 

145 

91 

182 

B6 

219 

DB 

 

 

35 

23 

72 

48 

109 

6D 

146 

92 

183 

B7 

220 

DC 

 

 

36 

24 

73 

49 

110 

6E 

147 

93 

184 

B8 

221 

DD 

 

 

37 

25 

74 

4A 

111 

6F 

148 

94 

185 

B9 

222 

DE 

 

 

 

(*) Indirizzi non disponibili con protocollo Modbus / not available addresses for the Modbus protocol 
(**)Indirizzo non disponibile con protocollo Galileo / not available addresse for the Galileo protocol 

Содержание MULTISCAN++/S1-32B

Страница 1: ...2019 Pagina 1 di 45 MULTISCAN S1 32B ATEX and SIL 1 certified INSTALLATION AND USE MANUAL SENSITRON S r l Viale della Repubblica 48 20010 CORNAREDO MI Italy Tel 39 02 93548155 Fax 39 02 93548089 E MAI...

Страница 2: ...urer s instructions OTHERWISE IT COULD FAIL TO PERFORM AS DESIGNED AND PERSONS WHO RELY ON THIS PRODUCT FOR THEIR SAFETY COULD SUFFER SEVERE PERSONAL INJURY OR DEATH The warranties made by Sensitron s...

Страница 3: ...B MT3896E Rev 1 15 10 2019 Pagina 3 di 45 THIS TECHNICAL MANUAL DESCRIBES THE PRODUCT IN ITS COMPONENTS THE INSTALLATION AND THE OPERATION OF THE SYSTEM THE CONFIGURATION SOFTWARE IS NOT INCLUDED SO P...

Страница 4: ...3 STG IN8 S REMOTE INPUT MODULE 17 2 1 STG OUT16 S REMOTE OUTPUT MODULE 18 2 1 1 STG 8REL RELAY EXPANSION BOARD 19 2 1 2 STG IN8 S AND STG OUT16 S MODULE ADDRESSING 19 2 1 3 DETECTOR IDENTIFICATION 2...

Страница 5: ...ludes 8 on board relays and the possibility to expand outputs up to 64 using remote STG OUT16 S modules and 8 relay boards Three alarm thresholds to be set for each detector The alarm threshold activa...

Страница 6: ...US or 1 closed Loop Fig 1 1 System block diagram 1 2 Technical specifications Technical specifications Housing Plastic box IP65 dim L 470 H 426 D 148 mm Inputs Max 32 detectors with RS485 communicatio...

Страница 7: ...s can now be drilled in the back of the box for wire passage We recommend you use an IP65 wire clamp at wire entrance to maintain the same protection level as the unit Secure the back of the unit to t...

Страница 8: ...part identification Box version 1 2 3 4 5 6 7 8 1 Power Supply 27 Vdc 4A 2 2 x 12V 7Ah batteries not included 3 RS232 serial port PC connection 4 RS485 serial boards 5 Relay outputs 8 6 8 detectors 4...

Страница 9: ...s 1 2 3 4 5 6 7 8 Rs485 linea1 Rs485 linea2 SD Card Rs232 for PC D3 switches Control panel language Language English Italian Spanish Portoguese Sw4 Sw3 Sw2 Sw1 ON OFF OFF OFF OFF OFF OFF OFF ON ON ON...

Страница 10: ...guage The series of SD2 dip switches must be set for Communication baud rate and protocol for unit compatibility with various gas detector versions and IN OUT modules Communication baud rate of the RS...

Страница 11: ...115 200 Bps can be set switch 1 OFF OFF Configurazione non usata Dip switch 4 and 5 Communication baud rate of the RS232 serial port for the communication with the PC Sw 4 Sw 5 Baud Rate ON ON 9600 B...

Страница 12: ...sumption please see the technical manual enclosed with gas detectors for this purpose Each device connected on the unit s RS485 bus must have its own univocal address STG IN8 S and STG OUT16 S address...

Страница 13: ...r a 100 m distance between the gas detector and STG IN8 S input module Detectors with 4 20 mA output directly connected to the unit 1 2 3 4 5 6 7 8 Control panel main board S Det 1 Det 2 Det 6 Det 8 F...

Страница 14: ...e of a recommended cable is a BELDEN 9841 or similar wire EIA RS485 data transmission wire Only connect detectors and IN and OUT modules in cascade Avoid tree or star connections since they reduce int...

Страница 15: ...iliario remoto From the control panel or from the remote auxiliary power supply Cavo twistato schermato 2x022 Belden 9841 o equivalente Twisted shielded 2x0 2 cable Belden 9841 or equivalent Bus 1 Bus...

Страница 16: ...lla centrale o dall alimentatore ausiliario remoto From the control panel or from the remote auxiliary power supply Cavo twistato schermato 2x022 Belden 9841 o equivalente Twisted shielded 2x0 2 cable...

Страница 17: ...Led DL1 Guasto WD WD Faul DL2 TX Data DL3 RX Data DL4 RTS Jp10 Resistenza di file linea EOL resistor Se il modulo l ultimo della linea chiudere Jp10 If the module is the last of the bus line close JP1...

Страница 18: ...and serial line Commutatori rotativi per l indirizzo del modulo Jp13 Communication Baud Rate setting Closed 115 000 bps Multiscan control panel Open 9 600 bps old Galileo Multiscan control panel Jp13...

Страница 19: ...Relay board connection to the output module 2 1 2 STG IN8 S and STG OUT16 S module addressing STG IN8 S and STG OUT16 S modules are addressed using the two rotary switches in RSW 1 and 2 hexadecimals...

Страница 20: ...33 88 58 125 7D 162 A2 199 C7 236 EC 15 0F 52 34 89 59 126 7E 163 A3 200 C8 237 ED 16 10 53 35 90 5A 127 7F 164 A4 201 C9 238 EE 17 11 54 36 91 5B 128 80 165 A5 202 CA 239 EF 18 12 55 37 92 5C 129 81...

Страница 21: ...collegato su bus detector position from 01 to 08 if IN 8 module or 00 is detector on the bus 1 Numero bus 1 4 bus number 1 4 Fig 2 4 3 Detector number indication 2 2 Programming by PC The MULTISCAN S1...

Страница 22: ...supervising software by using the Modbus protocol Remote management of the control panel via a supervising software made by Sensitron future availability For technical features and use of TCP IP modu...

Страница 23: ...switch ON the control panel needs programming Fig 3 1 a Warm Up screen The control panel programming must be performed just by the Personal Computer with the dedicate configuration software see the p...

Страница 24: ...through the parameter under change fields At any display level the ESC key will switch back to the previous view Pressing twice the ESC key you will go back to the main screen The same at any display...

Страница 25: ...than one input channel enters in alarm state simultaneously alarms are displayed according to the following rules 1 The events are ordered by severity as follows Over range Alarm 3 Alarm 2 Alarm 1 2...

Страница 26: ...yet reset FAULT The fault condition will be activated in the following situations 1 Short circuit or open circuit in a detecting circuit 2 Removal of a remote gas detector or IN and OUT modules 3 Unde...

Страница 27: ...r TEST will not be activated even if an alarm event associated is taking place while the relay is in TEST MAINTENANCE mode EXCEPTION In case the system just includes one channel only it will be possib...

Страница 28: ...these various options are available The three levels are as follows 1 OPERATOR level O 2 MAINTENANCE level M 3 ENGINEER level E Once logged in with a certain level a letter in the top right side of t...

Страница 29: ...n the Operator level offers the following options 1 MENU gets the user into a sub menu just for the Event Log the printer options and the System info 2 LOGOUT logs out the active user 4 LOGIN opens th...

Страница 30: ...ons allowed in the Engineer level main screen are the same as for the Maintenance level In case of Alarm and or Fault the system will switch automatically to ALARM or FAULT mode In effect the only sit...

Страница 31: ...E EVENT the list shows the actually active events If there are active Alarms and active Faults or Emergency situations these will be shown by splitting the window in two as below In the upper side the...

Страница 32: ...vent the screen will automatically switch to the Active Events list and the buzzer will sound Until the event is acknowledged the user cannot go back to the main screen In the upper figures 3 5 1 a b...

Страница 33: ...As described above there are two situations 1 the user is already logged in for a previous operation that requires login In this case pressing 2 RESET the screen image will simply refresh and delete...

Страница 34: ...opens a query asking to select the period to be observed by entering the start and the end date Fig 3 5 2 b Select period dialogue window The date should be introduced in a 2 digit format for day mon...

Страница 35: ...enters the Alarm events list Using the up down arrow keys one may search in the Alarm event log FLT SYSTEM Choosing the Fault System LOG option enters the faults and system events list Using the up do...

Страница 36: ...est in the different menu The printer can be connected and disconnected at any time as required REAL TIME This option switches the printer to on line mode and requires that a printer be continuously c...

Страница 37: ...d to allow entering one of the three user levels OPERATOR MAINTENANCE or ENGINEER level see the related chapter 3 3 User levels Fig 3 7 a Login dialogue window For the OPERATOR level login is only req...

Страница 38: ...the available function buttons depend on the user level 3 8 1 Zones In the zones screen moving up and down with the arrow keys through the zones list and pressing ENTER one gets into the modules scre...

Страница 39: ...trying to put in Test Maintenance mode the only zone defined Until the number of zones to put in Test Maintenance mode does not exceed the defined limits 50 the selected items will change the status...

Страница 40: ...ressing ENTER one gets into the modules screen Fig 3 8 2 Videata Moduli e modalit operative alla pressione del tasto 3 Modulo 3 8 3 Relay outputs In the modules screen moving up and down with the arro...

Страница 41: ...ossible to put in TEST mode just parts of the system at user level Maintenance or Engineer If more than half of the system selected a warning screen will pop up Until the number of relays to put in Te...

Страница 42: ...ith the arrow keys through the modules list and pressing ENTER one gets into the detectors screen Fig 3 8 4 a Detectors screen and options available pressing 3 Channel Using the up down arrow keys one...

Страница 43: ...in TEST mode just parts of the system when user level is Maintenance or Engineer If more than half of the system is selected a warning screen will pop up As far as the number of channels to put in Te...

Страница 44: ...10 2019 Pagina 44 di 45 Fig 3 8 3 c Detector details screen in Engineer level Unlike the above this screen seen as Engineer level allows changing the Detector s details See chapter 4 PC Configuration...

Страница 45: ...es not make the manufacturer liable and the manufacturer reserves the right to make any changes that it retains will be useful to improve the product For further information contact Sensitron S r l Te...

Отзывы: