background image

 

©2018 Sensing-labs 

Sensing Labs SenlabA 4MA-LAB-

xx

NS 

 User guide 

 Version 2 

 REV D 

Warning, take care to respect the operating temperature of the senlab:

-20°C to +70°C for outdoor and 0°C to +55°C for indoor version

 

Thank you for your choosing our Senlab product! 
We hope you will find the instructions on this user manual clear and easy to follow. 

General overview 

 

The Senlab Analog (SenlabA) sensor 

is a smart LoRaWAN™ radio device 

with an 

analog 4-20mA input. 
The SenlabA product is intented to be connected to 

any sensors with 4-20mA 

output

, to it 50cm free ended cable. 

 

 

Any question about your sensor compatibility? Please contact your distributor.

 

Part number 

Casing 

type 

Protection 

level 

Dimension 

4MA-LAB-13NS 

Outdoor 

IP67 

102x56x35mm 

4MA-LAB-41NS 

Indoor v2 

IP30 

91.5x50x25mm 

 

 

 

  

 

 

 

3 steps are required to make your SenlabA fully operational, described below.  

      

 

 

Warning, the 4-20mA current loop must be powered by an external power supply, 
or by the sensor (transmitter).
The SenlabA is only passive current sensor, it doesn't provide power for the loop.

Provisioning 

of the device

On-site 

installation

Activation of 

the device

 

Outdoor 

 

Indoor v2 

4-20mA 

Содержание SenlabA 4MA-LAB-13NS

Страница 1: ...SENSING LABS SAS Cap Om ga Rond point Benjamin Franklin CS 39521 34960 Montpellier Cedex 2 France www sensing labs com SenlabA 4MA LAB xxNS User guide SENSING LABS VERSION 02 REV D FEBRUARY 2018...

Страница 2: ...product is intented to be connected to any sensors with 4 20mA output to it 50cm free ended cable Any question about your sensor compatibility Please contact your distributor Part number Casing type P...

Страница 3: ...ices By your distributor more often By yourself if you have your own SLsetting tool In all cases you have to refer to parameter list described into the Application features chapter to fit to your use...

Страница 4: ...r version Screw the rear side of the product to the wall with countersunk screws make sure the screw heads don t exceed from the plastic side once installed Outdoor version Use plastic cable ties with...

Страница 5: ...o transmissions will be stop until activation process That means you need a physical access to the Senlab to active it again There are 2 ways to deactivate a Senlab Over the Air By sending a Downlink...

Страница 6: ...ge start_event Happens when device is restarted on the field BOOL Configuration requests Parameter ID Description Type Unit Range Datalog configuration ID request_write_datalog_cfg log_period Device w...

Страница 7: ...maximum battery level used for battery life calculation expressed in mAs Uplink message DATALOG FPort 3 format valid for one log per transmission only ID 1B BATTERY_LEVEL 1B Internal data n bytes Log...

Страница 8: ...ivation lost you need to activate the device again 5 Close the casing 1 Send the configuration request request_reset_battery_level to the device using your application ATTENTION EN There is a risk of...

Страница 9: ...ramifications of their applications acknowledge and agree that they are solely responsible for all legal regulatory and safety related requirements concerning their products and any use of the produc...

Отзывы: