Provisioning of the device 

 
You have to be sure that your 

Senlab device has been well commissioned

 to be able to 

reach your LoRaWAN network. 

 

Contact if needed your distributor to get your Senlab configuration 

 

Required information for provisioning the device into your LoRa system are listed in 
the following table: 

 

 

 

* = If asked when ordering, devices are already provisioned into your SLgateway. 
      If not, you need these parameters. 

 

Important: 

Applicative configuration of Senlab device can be done:

 

-

 

At factory (for minimal batch of 1000 devices) 

-

 

By your distributor (more often) 

-

 

By yourself (if you have your own SLsetting tool) 

 

In all cases, you have to refer to parameter list

 described into the Application 

features chapter to fit to your use case and get a “Plug&Play” device.

 

 

Application configuration can also be dynamically 

adjusted Over The Air

 

 

 

Warning, don’t unprovision device from your system before stopping it!

(refer application features to stop the application via RF)

 

devEUI

 

appEUI

 

appKey

 

appSkey

 

NwkSkey

 

netId

 

devAddres

Case 1 : OTAA / PUBLIC 

Typical configuration for Network 
Operator based architecture

 

required 

required

   

 

 

 

Case 2 : ABP / PUBLIC  

Typical configuration for Private 
mono gateway network

 

 

 

required

 

required

 

 

required

 

Case 3 : ABP / PUBLIC  

Sensing-Labs SLgateway V2 
configuration (local network)

 

Optional*

   

Optional*

 

Optional*

 

Optional*  Optional*

 

Содержание SenlabA 4MA-LAB-13NS

Страница 1: ...SENSING LABS SAS Cap Om ga Rond point Benjamin Franklin CS 39521 34960 Montpellier Cedex 2 France www sensing labs com SenlabA 4MA LAB xxNS User guide SENSING LABS VERSION 02 REV D FEBRUARY 2018...

Страница 2: ...product is intented to be connected to any sensors with 4 20mA output to it 50cm free ended cable Any question about your sensor compatibility Please contact your distributor Part number Casing type P...

Страница 3: ...ices By your distributor more often By yourself if you have your own SLsetting tool In all cases you have to refer to parameter list described into the Application features chapter to fit to your use...

Страница 4: ...r version Screw the rear side of the product to the wall with countersunk screws make sure the screw heads don t exceed from the plastic side once installed Outdoor version Use plastic cable ties with...

Страница 5: ...o transmissions will be stop until activation process That means you need a physical access to the Senlab to active it again There are 2 ways to deactivate a Senlab Over the Air By sending a Downlink...

Страница 6: ...ge start_event Happens when device is restarted on the field BOOL Configuration requests Parameter ID Description Type Unit Range Datalog configuration ID request_write_datalog_cfg log_period Device w...

Страница 7: ...maximum battery level used for battery life calculation expressed in mAs Uplink message DATALOG FPort 3 format valid for one log per transmission only ID 1B BATTERY_LEVEL 1B Internal data n bytes Log...

Страница 8: ...ivation lost you need to activate the device again 5 Close the casing 1 Send the configuration request request_reset_battery_level to the device using your application ATTENTION EN There is a risk of...

Страница 9: ...ramifications of their applications acknowledge and agree that they are solely responsible for all legal regulatory and safety related requirements concerning their products and any use of the produc...

Отзывы: