Installation
2.0 Installation
2.1 Pre-Installation
Before installing the inverter, read the entire Installation section. The more
thorough you plan in the beginning, the better your inverter needs will be met.
WARNING:
Installations should be performed by quali
fi
ed
personnel, such as a licensed or certi
fi
ed electrician. It is the
installer’s responsibility to determine which safety codes apply and
to ensure that all applicable installation requirements are followed.
Applicable installation codes vary depending on the speci
fi
c location
and application of the installation.
Info:
Review the “Important Product Safety Information” on page
ii and the “Important Battery Safety Instructions” on page iii before
any installation.
The basic system diagrams shown in Figures 2-3 & 2-4
should be reviewed
to assist you in planning and designing your installations.
2.1.1 Unpacking and Inspection
Carefully remove the MM Series unit from its shipping container and inspect
all contents. Verify the following items are included:
•
MM Series inverter
•
Red and black DC terminal covers
•
AC access cover with two screws
•
Two 1/2” hex-head Flange nuts (installed on the DC terminals)
•
Battery Temperature Sensor (
MM1212 & MM1212-G models only
)
•
MM Series Owner’s Manual
If items appear to be missing or damaged, contact your authorized
Magnum Energy dealer or Sensata Technologies.
If at all possible, keep your shipping box. It will help protect your inverter
from damage if it ever needs to be returned for service.
Save your proof-of-purchase as a record of your ownership; it will also be
needed if the unit should require in-warranty service.
Record the unit’s model and serial number in the front of this manual in case
you need to provide this information in the future.
2.2
Locating and Mounting the Inverter
WARNINGS:
• Do not mount the inverter near any
fl
ammable or combustible
fl
uid or components.
• Provide adequate clearance/ventilation to the inverter.
• Mount only on a “non-combustible” surface.
• Maximum ambient temperature around the inverter must not
exceed 77°F (25°C) to meet power speci
fi
cations.
The inverter should only be installed in a location that meets the following
requirements:
Clean and Dry
– The inverter should not be installed in an area that allows
dust, fumes, insects, or rodents to enter or block the inverter’s ventilation
openings. This area also must be free from any risk of condensation, water,
or
any other liquid that can enter or fall on the inverter. The inverter uses stainless