![Sensata MAGNUM ENERGY MM Series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/sensata/magnum-energy-mm-series/magnum-energy-mm-series_owners-manual_1243183010.webp)
© 2016 Sensata Technologies
4
Introduction
Figure 1-3, Front and Back Side Features
Front Side
9
10
11
12
16
17
15
= Power cord with
MM1212-G only
15. AC Output Connection –
AC knockout (output) for hardwiring (
MM612
& MM1212 models only
).
Note:
MM1212-G models include an attached
3 ft. standard plug-in power cord.
16. AC Input Connection
–
AC knockout (input) for hardwiring (
MM612
& MM1212 models only
).
Note:
MM1212-G models have a GFCI outlet.
17. DC Ground Terminal –
this connection is used to tie the exposed chassis
of the inverter to the DC grounding system. This terminal accepts CU/AL
conductors from #14 AWG to #6 AWG (2.1 mm
2
to 13.3 mm
2
).
Figure 1-4, Left Side Features
Back Side
13
14
1.6
Battery Temperature Sensor (MM1212 & MM1212-G)
A plug-in external Battery Temperature Sensor (BTS) is provided for units with
the battery charger feature. When installed, the BTS automatically adjusts
the battery charger’s BULK, ABSORB, and FLOAT voltage set-points based on
temperature for better charging performance and longer battery life. If the
temperature sensor is NOT installed and the batteries are subjected to large
temperature changes, battery life may be shortened.
Figure 1-5, Battery Temperature Sensor
FRONT VIEW
SIDE VIEW
~1"
(2.6 cm)
~½”
(~1.3 cm)
0.375" diameter
(~1 cm)
Cable
~¾”
(~2 cm)
~2"
(5.1 cm)
Содержание MAGNUM ENERGY MM Series