Sensafe Chlorine eXact EZ Скачать руководство пользователя страница 3

3

Sensafe.com

CHLORINE EXACT

®

 EZ OVERVIEW

YOUR NEW CHLORINE EXACT EZ PHOTOMETER IS IDEAL FOR 
TESTING AND MAINTAINING YOUR DRINKING WATER AND FOOD 
PROCESS WATER.

SAMPLE CELL - 4 ML

Built-in plastic 4mL cell 

for collecting your water 

sample

LCD DISPLAY

Displays results 

and test name

LIGHT SOURCE

Uses 525nm 

wavelength and 

11mm path-length 

for testing

READ BUTTON

Starts test timer

MENU BUTTON

Cycles through 

available tests

BASE

Install/replace batteries here 

(IP67 rated waterproof)

RESULT 

UNITS

LOW 

BATTERY

LCD DISPLAY

ZERO/ON BUTTON

Turns the meter 

on and creates a 

baseline for your 

water testing

CELL COVER

Covers the cell for 

mixing and bright 

light situations

Protected against the effects 

of immersion in water to depth 

between 15cm and 1m

Part no.

  486204

SCREW

Unscrew to 

remove base

INSTALL “AAA” BATTERIES (NOT INCLUDED)

1.  Use a #4 Phillips head screwdriver to remove the screw 

from the base of your Chlorine eXact

®

 EZ

 

.

2.  Remove the base.
3.  Install Four (4) new AAA batteries as illustrated inside 

your photometer’s battery compartment. We recommend 
using high quality batteries.

4.  Replace the base 

fi

 rmly with pressure while tightening the 

screw. The meter will turn on automatically.

5.  Tighten the screw with #4 Phillips head screwdriver. Be 

sure not to over tighten.

Содержание Chlorine eXact EZ

Страница 1: ...QUICK START GUIDE Chlorine ADVANCED PHOTOMETER SYSTEM DIGITAL ACCURACY FOR RELIABLE WATER CARE...

Страница 2: ...DPD 1 Combined Chlorine DPD 3 Total Chlorine DPD 4 Total Chlorine High and pH WHAT YOU WILL NEED TO GET STARTED Four 4 AAA batteries 4 Phillips head screwdriver Note This system has been calibrated f...

Страница 3: ...Turns the meter on and creates a baseline for your water testing CELL COVER Covers the cell for mixing and bright light situations Protected against the effects of immersion in water to depth between...

Страница 4: ...the cell 3 times with the water sample to be tested and FILL to the top to begin test 2 1 POWER ON PHOTOMETER Press the button to power on the Chlorine eXact EZ 3 SELECT TEST Press and re press the b...

Страница 5: ...use a gentle constant back and forth motion 2 strokes per second until the timer displays 1 Remove and discard the strip 6 READ RESULTS READ result displayed as Free Chlorine This result is automatica...

Страница 6: ...ve and discard the strip 10 This procedure is a continuation from Free Chlorine Test Method on previous pages DO NOT DISCARD SAMPLE FROM FREE CHLORINE TEST REMOVE STRIP Remove one eXact Strip Micro CL...

Страница 7: ...orine reaction at all levels Chlorine Dioxide ClO2 Color similar to free chlorine reaction at all levels Copper Cu 2 Color development is reduced above 10 ppm mg L Iodine I2 Color similar to free chlo...

Страница 8: ...imes with the water sample to be tested and FILL to the top to begin test 2 1 POWER ON PHOTOMETER Press the button to power on the Chlorine eXact EZ 3 SELECT TEST Press and re press the button until t...

Страница 9: ...count up for 120 seconds NOTE Standard Method 4500 Cl G procedure for total chlorine requires the reading to be made after 2 minutes from the time the KI is added For compliance testing you must time...

Страница 10: ...3 times with the water sample to be tested and FILL to the top to begin test 2 1 POWER ON PHOTOMETER Press the button to power on the Chlorine eXact EZ 3 SELECT TEST Press and re press the button unti...

Страница 11: ...ously DIP the eXact Strip by submerging all pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the timer displays 1 Remove and discard the strip The display...

Страница 12: ...with the water sample to be tested and FILL to the top to begin test 2 1 POWER ON PHOTOMETER Press the button to power on the Chlorine eXact EZ 3 SELECT TEST Press and re press the button until the di...

Страница 13: ...ntdown and simultaneously DIP the eXact Strip by submerging all pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the timer displays 1 Remove and discard t...

Страница 14: ...liquid over the side Test immediately after filling the cell with the water sample To obtain optimal accuracy when testing outdoors sunlight use the cell cover when zeroing and reading the sample Due...

Страница 15: ...d how to videos For additional technical support call 803 329 9712 Industrial Test Systems Inc 1875 Langston Street Rock Hill SC 29730 800 861 9712 or 803 329 9712 its sensafe com sensafe com ITS Euro...

Страница 16: ...e com to describe the problem and obtain a return authorization form before returning the photometer to ITS Damage caused by improper packing of the photometer for return shipment to ITS will not be c...

Страница 17: ...icro CL DPD 3 for Combined Chlorine the eXact Strip Micro CL DPD 4 for Total Chlorine and the eXact Strip Micro Cd DPD 1 for Chlorine Dioxide meet your reportable testing requirements because the eXac...

Страница 18: ...18 2017 Industrial Test Systems Inc Printed in USA NOTES...

Страница 19: ...19 Sensafe com NOTES...

Страница 20: ...s Inc Rock Hill SC USA EXACT MICRO TESTS REAGENTS PARAMETER TEST PART RANGE ppm BEST ACCURACY OF TESTS Chlorine Free DPD 1 1 486637 0 01 12 0 5 100 Chlorine Combined DPD 3 2 486638 0 01 12 0 5 100 Chl...

Отзывы: