GREEN FLASH - Battery is charging in either Boost (steady flash LED) or Refresh mode
(2x short flash LED)
GREEN - Maintaining battery in Eco-float mode.
RED/YELLOW - Battery is connected backwards. Correct connections and retry.
YELLOW - Charger in initial power-on sequence.
RED - No charger output. Verify battery and source voltage are connected.
GREEN/YELLOW - Overvoltage Protection, charger will return to normal operation once
externally caused over voltage condition is removed.
OFF - AC source not connected. Verify source is connected and has proper
voltage and frequency.
Getting Started
The charger automatically starts in Boost mode at power-on or after a battery discharge. It remains in Boost mode until the
battery is fully charged. The charger then shifts to Eco-float mode to lengthen battery life. Refresh mode runs periodically to
insure that the battery remains fully charged. This cycle continues until the next discharge event.
Operation
PATENTED US 9,270,140; 9,385,556; 9,413,186; 9,509,164; 9,948,125
Battery Charger
Need Help?
CONTACT SENS CUSTOMER SERVICE:
800-742-2326 / 303-678-7500 / [email protected]
3.98
6.46
5.65
1.46
4X .266
3.41
NOTES:
THIS DRAWING IS FOR REFERENCE ONLY.
1.
SUPPLIED WITH 6FT AC CORD WITH NEMA 5-15 PLUG.
2.
SUPPLIED WITH 6FT DC CORD WITH RING TERMINALS.
3.
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
DIMENSIONS & TOLERANCES
PER ASME Y14.5 - 2009
20
B
SENS - MGLE
SHEET 1 OF 1
SENS MICROGENIUS LE OUTLINE DRAWING
8/8/2018
ERS
REV
DOCUMENT NUMBER
SIZE
DESCRIPTION
NAME
DATE
CHECKED
DRAWN
THIRD ANGLE PROJECTION
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN
INCHES
DEFAULT TOLERANCES:
ANGLES 1
TWO PLACE DECIMAL .015
THREE PLACE DECIMAL .005
DO NOT SCALE DRAWING
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF STORED ENERGY SYSTEMS, LLC. ANY
REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN
PERMISSION OF STORED ENERGY SYSTEMS, LLC. IS PROHIBITED.
© STORED ENERGY SYSTEMS, LLC
1840 INDUSTRIAL CIRCLE
LONGMONT, CO 80501
303-678-7500
WWW.SENS-USA.COM
Enclosure rated IP67
Mount vertically for optimal
cooling using #8 - 1/4-20 inch or
M4 - M6 metric screws
Operating Temp -25C to +70C
• 12V, 6A full spec to +50C
• 12V, 10A and 24V, 5A full
spec to +40C
Time
12.8/25.6V
0
Current accepted
by battery
DYNAMIC BOOST
CHARGE MODE
HELIX
ECO-FLOAT
MODE
HELIX
REFRESH
MODE
14.5/29.0V
14.3/28.6V
Charger determines time in Boost
charge mode automatically
~10 hours
~2
hours
~10 hours
~2
hours
Vo
lta
ge
Cu
rr
ent
Mounting
LEDs/Troubleshooting
GREEN - Battery is charged. Boost cycle complete, charger now in Eco-float.
YELLOW FLASH - Check battery or load. Boost mode time limit expired indicating exces-
sive load, battery capacity is too large or battery has an internal short.
RED/RED FLASH - Battery bad or disconnected. Battery voltage dropped below preset
threshold within one hour of boost termination. Verify battery
connected. Battery unable to hold charge or has an internal short.
OFF - Battery charging not yet complete.
Note - battery status updated every 100 seconds
Dimensions in inches