background image

Important safety instructions

Important safety instructions

• Read this instruction manual.

• Keep this instruction manual. Always include this instruction manual

when passing the device on to third parties.

• Heed all warnings and follow all instructions.

• Clean the device only with a slightly damp cloth.

• Do not place the device near any heat sources such as radiators, stoves,

or other devices (including amplifiers) that produce heat.

• Only use attachments/accessories specified by Sennheiser. 

• When replacement parts are required, only use replacement parts

specified by Sennheiser or those having the same characteristics as the
original part. Unauthorized substitutions may result in fire, electric
shock, or other hazards.

• Refer all servicing to qualified service personnel.

Servicing is required if the device has been damaged in any way, liquid
has been spilled, objects have fallen inside, the device has been exposed
to rain or moisture, does not operate properly or has been dropped.

• WARNING: To reduce the risk of short circuits, do not use the device near

water and do not expose it to rain or moisture.

Intended use

Intended use of the ew 100 G3 series devices includes:

• having read these instructions especially the chapter “Important safety

instructions”,

• using the devices within the operating conditions and limitations

described in this instruction manual.

“Improper use” means using the devices other than as described in these
instructions, or under operating conditions which differ from those
described herein.

SKP100_529675_0409_Sp9.book  Seite 2  Donnerstag, 9. April 2009  1:48 13

Содержание G3 100 Series

Страница 1: ...Instruction Manual SKP 100 C M Y CM MY CY CMY K ...

Страница 2: ...9 Muting the audio signal or deactivating the RF signal 9 Selecting a standard display 10 Using the operating menu 11 The buttons 11 Overview of the operating menu 11 Working with the operating menu 12 Adjusting settings via the operating menu 13 The main menu Menu 13 The extended menu Advanced Menu 14 Synchronizing the plug on transmitter with a receiver 17 Cleaning the plug on transmitter 18 Rec...

Страница 3: ...tric shock or other hazards Refer all servicing to qualified service personnel Servicing is required if the device has been damaged in any way liquid has been spilled objects have fallen inside the device has been exposed to rain or moisture does not operate properly or has been dropped WARNING To reduce the risk of short circuits do not use the device near water and do not expose it to rain or mo...

Страница 4: ...h on several transmission systems can be operated simultaneously on the preset frequencies without causing intermodulation interference The frequency bank system The plug on transmitter is available in 6 UHF frequency ranges with 1 680 transmission frequencies per frequency range Each frequency range A E G offers 21 frequency banks with up to 12 channels each Each of the channels in the frequency ...

Страница 5: ...aded from the SKP 100 G3 product page on our website at www sennheiser com The frequency bank U allows you to freely select and store transmission frequencies It might be that these transmission frequencies are not inter modulation free Delivery includes The packaging contains the following items 1 SKP 100 G3 plug on transmitter 2 AA size batteries 1 5 V 1 instruction manual 1 frequency informatio...

Страница 6: ...g of XLR 3 socket Infra red interface Display panel backlit in orange UP button 왖 DOWN button 왔 Operation and battery status indicator red LED lit ON flashing LOW BATTERY ON OFF button serves as the ESC cancel key in the operating menu MUTE switch SET button Battery compartment cover 쐋 SKP100_529675_0409_Sp9 book Seite 5 Donnerstag 9 April 2009 1 48 13 ...

Страница 7: ...l AF Modulation of the plug on transmitter with peak hold function Frequency Current transmission frequency Name User selectable name Transmission icon RF signal is being transmitted Lock mode icon Lock mode is activated P pilot tone Pilot tone transmission is activated MUTE Microphone input is muted Battery status Charge status MHz 533 875 ew100 G3 MUTE P AF approx 100 approx 70 approx 30 charge ...

Страница 8: ...ocks into place with an audible click Charging the accupack 왘 Remove the BA 2015 accupack optional accessory 왘 Insert the BA 2015 accupack into the L 2015 charger accupack and charger are optional accessories Plugging the plug on transmitter onto a microphone 왘 Plug the microphone s XLR 3M socket onto the transmitter s XLR 3F socket 왘 Tighten the locking ring in the direction of the arrow The L 20...

Страница 9: ...layed You can switch the plug on transmitter on and deactivate the RF signal on switch on For more information see below 왘 Press the ON OFF button until OFF appears on the display panel The red ON LED goes off and the display panel turns off When in the operating menu pressing the ON OFF button will cancel your entry ESC function and return you to the current standard display 왘 Press the SET butto...

Страница 10: ... The plug on transmitter reacts as indicated in the table 왘 Press the ON OFF button Locked appears on the display panel 왘 Press the UP button 왖 Unlock appears on the display panel 왘 Press the SET button The lock mode is temporarily deactivated How you are using the plug on transmitter determines how long the lock mode remains deactivated Setting Slide the MUTE switch Function AF On Off to the left...

Страница 11: ...ion icon is displayed MUTE is not displayed You can also deactivate the RF signal on switch on For more infor mation refer to the chapter Switching the plug on transmitter on off on page 8 Using the ON OFF button you can also activate deactivate the RF signal during operation To do so briefly press the ON OFF button and proceed as described on page 8 왘 Press the UP button 왖 DOWN button 왔 to select...

Страница 12: ... 13 Name Enters the transmitter name 14 Auto Lock Activates deactivates the automatic lock mode 14 Advanced Calls up the extended menu Advanced Menu 14 Exit Exits the operating menu and returns to the current standard display Extended menu Advanced Menu Tune Sets the transmission frequencies for the frequency bank U 15 Special function Sets a channel and a transmission frequency for the frequency ...

Страница 13: ...the UP button 왖 DOWN button 왔 to change to the Sensitivity menu item The current setting of the selected menu item is displayed 왘 Press the SET button to call up the menu item 왘 Press the UP button 왖 DOWN button 왔 to adjust the input sensitivity 왘 Press the SET button to store the setting 왘 Press the ON OFF button to cancel the entry The current standard display appears on the display panel 왘 Pres...

Страница 14: ...peakers with loud voices or loud music passages cause overmodulation in the trans mission link The audio level display AF shows full deflection for the duration of the overmodulation correctly The audio level display AF shows full deflection only during the loudest passages too low The transmission link is undermodulated This results in a signal with high background noise Adjust a low input sensit...

Страница 15: ...ended menu Advanced Menu Setting transmission frequencies and the frequency bank U Tune When you have selected one of the system banks and then select the Tune menu the plug on transmitter automatically switches to channel 1 of the frequency bank U In this case U 1 briefly appears on the display panel Upon delivery the channels of the frequency bank U are not assigned a transmission frequency Via ...

Страница 16: ...selec tion appears 왘 Press the SET button The frequency selection appears Mode Function AF On Off When the switch is in the MUTE position no audio signal is transmitted RF On Off When the switch is in the MUTE position the RF signal is deactivated Disabled The muting function is deactivated SET Select the MHz value and confirm Select the kHz value store the setting 543 200 MHz Tune 548 200 MHz B C...

Страница 17: ...reset default settings Reset When resetting the plug on transmitter only the selected settings for the pilot tone and for the frequency bank U remain unchanged For an overview of the factory preset default settings refer to the supplied frequency information sheet Displaying the software revision Software Revision You can display the current software revision of the plug on transmitter Transmitter...

Страница 18: ...ion of the plug on transmitter with the receiver individual operation refer to the instruction manual of the receiver This information is marked with the icon Alternatively you can set the channel on the plug on transmitter manually 왘 Make sure that you set the plug on transmitter to the same frequency bank and the same channel as the receiver see page 13 If you still cannot establish a transmissi...

Страница 19: ...ary from about 10 m to about 150 m There should be a free line of sight between plug on transmitter and receiving antennas To avoid overloading the receiver observe a minimum distance of 5 m between plug on transmitter and receiving antennas The plug on transmitter uses the microphone body as an antenna therefore microphones with a metal casing should be used for best signal transmission for multi...

Страница 20: ...l as the receiver Synchronize the plug on transmitter with the receiver see page 17 Transmissionrange is exceeded Reduce the distance between plug on trans mitter and receiving antennas RF signal is deacti vated RF Mute Activate the RF signal see page 9 Receiver is muted Cancel the muting on the receiver see the instruc tion manual of the receiver RF signal available no audio signal MUTE appears o...

Страница 21: ...owing SKP 100 G3 accessories are available from your specialist dealer Cat No Accessory 009950 BA 2015 accupack 009828 L 2015 charger 005232 POP 1 pouch with belt clip SKP100_529675_0409_Sp9 book Seite 20 Donnerstag 9 April 2009 1 48 13 ...

Страница 22: ...m Sennheiser HDX AF frequency response 80 18 000 Hz Signal to noise ratio 1 mV RF peak deviation 110 dBA THD 0 9 Max input voltage 3 3 Vrms Input impedance 60 kΩ unbalanced Adjustment range of input sensitivity 48 dB adjustable in steps of 6 dB Temperature range 10 C to 55 C Power supply 2 AA size batteries 1 5 V or BA 2015 accupack Nominal voltage 2 4 V Power consumption at nominal voltage with s...

Страница 23: ...that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance w...

Страница 24: ...Sennheiser electronic GmbH Co KG Am Labor 1 30900 Wedemark Germany www sennheiser com Printed in Germany Publ 01 09 529675 A01 C M Y CM MY CY CMY K ...

Отзывы: