Receiving Part 

Detecting Part 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ing Part 

 
 

2.

 

Specification 

 
 
 
 

 

 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

-5- 

Type 

AC 220V, separation type 

Industrial single circuit 

Diffusion 

Immediate alarm type 

Combustible catalytic sensor 
circuit 

Explosion-proof type 

Power 

AC 220V, 60Hz 

Power 

consumption 

9W 

Temperature 

-20~50 

Density to 

alarm 

20% LEL 

Power led 

LED green light 

Alarm sign 

LED yellow light and buzzer sound 

Breakdown 

LED red light 

Dimension 

140

×

200

×

78 mm 

Output signal 

Voltage : 12V 

Relay: COM, NO, NC 

Weight 

1.5Kg 

Model 

SI560 LPG 

SI560 LNG 

Sensor 

Combustible catalytic sensor 

Gas 

LPG 

LNG 

Operation 

Temp. 

-20~50

°

Exproof 

Ex D ll B T4 

Ex D ll C T3 

Dimension 

130

×

107

×

73 

Receving 

part 

Содержание SI-560

Страница 1: ...Copyright SENKO CO LTD INSTRUCTIONS MANUAL LNG LPG GAS DETECTOR SI 560...

Страница 2: ...or warranty repair SENKO will determine the nature and responsibility for the defect In all cases the warranty is limited to the original cost of the equipment Any misuse of equipment is the customers...

Страница 3: ...Copyright SENKO CO LTD Table of contents Product introduction 3 1 Description 4 2 Sensor specification 5 3 Electric wiring installation 6 4 Operation caution 7 Notice for user 9 2...

Страница 4: ...ation SI560LPG is also robust for the change of surrounding temperature and input voltage and designed to consume the minimum electric power Automatic shut off gas valve is operated by transmitting a...

Страница 5: ...ription Instrument Overview 4 NUMBER NAME FUNCTION 1 VOLUME Gas volume display 2 Power LED Main power 3 Warning LED Gas leakage warning 4 Fail LED Sensor fail warning 5 Test Circuit test 6 Restore Res...

Страница 6: ...e Power AC 220V 60Hz Power consumption 9W Temperature 20 50 Density to alarm 20 LEL Power led LED green light Alarm sign LED yellow light and buzzer sound Breakdown LED red light Dimension 140 200 78...

Страница 7: ...installation In case of connection at detection part connect properly by matching the color on terminal block with that on detection part Otherwise it could fail to perform as designed and persons wh...

Страница 8: ...tance from the floor to the upper portion detection part at 30 cm or less LNG Please install with the distance from the ceiling to the upper portion of detection part at 30 cm or less Use of Signal fo...

Страница 9: ...ine connected to detection part fault lamp is on and alarm sound rings Caution 1 Do not use any inflammable when alarm sounds 2 While alarm sound is on do not operate any switches for ventilation fan...

Страница 10: ...should be performed at the same or similar environment as that of the instrument use temperature pressure and humidity If temperature changes sharply during use of the instrument for instance using t...

Отзывы: