Caution 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ing Part 

 

 

If buzzer stop switch is pressed, buzzer sound stops. 

 

 

If returning switch is pressed about one second, it returns to the initial setting. 

                (but, if detection part has more gas than alarm density, alarm will not return) 

 

In case of disconnection of line connected to detection part, fault lamp is on 

and alarm sound rings.   

 

 

 

 

 
 

 

 

 

Caution   

  1. Do not use any inflammable when alarm sounds.   

 
  2. While alarm sound is on, do not operate any switches for ventilation fan, 

  lighting and etc. 
 

  3. heck and restore by investing the cause of gas leakage. 
 

                4. In case that reason is unknown for gas leakage, contact gas company or   

distributor for check-up.   

 

 

  Check-Up   

                  1. Conduct check-up more than once each month and the check-up of detection   

sensor within one year. 

 

 

 

 
 

 
 

 
 

 
 
 
 
 
 
 

-8- 

 

Содержание SI-560

Страница 1: ...Copyright SENKO CO LTD INSTRUCTIONS MANUAL LNG LPG GAS DETECTOR SI 560...

Страница 2: ...or warranty repair SENKO will determine the nature and responsibility for the defect In all cases the warranty is limited to the original cost of the equipment Any misuse of equipment is the customers...

Страница 3: ...Copyright SENKO CO LTD Table of contents Product introduction 3 1 Description 4 2 Sensor specification 5 3 Electric wiring installation 6 4 Operation caution 7 Notice for user 9 2...

Страница 4: ...ation SI560LPG is also robust for the change of surrounding temperature and input voltage and designed to consume the minimum electric power Automatic shut off gas valve is operated by transmitting a...

Страница 5: ...ription Instrument Overview 4 NUMBER NAME FUNCTION 1 VOLUME Gas volume display 2 Power LED Main power 3 Warning LED Gas leakage warning 4 Fail LED Sensor fail warning 5 Test Circuit test 6 Restore Res...

Страница 6: ...e Power AC 220V 60Hz Power consumption 9W Temperature 20 50 Density to alarm 20 LEL Power led LED green light Alarm sign LED yellow light and buzzer sound Breakdown LED red light Dimension 140 200 78...

Страница 7: ...installation In case of connection at detection part connect properly by matching the color on terminal block with that on detection part Otherwise it could fail to perform as designed and persons wh...

Страница 8: ...tance from the floor to the upper portion detection part at 30 cm or less LNG Please install with the distance from the ceiling to the upper portion of detection part at 30 cm or less Use of Signal fo...

Страница 9: ...ine connected to detection part fault lamp is on and alarm sound rings Caution 1 Do not use any inflammable when alarm sounds 2 While alarm sound is on do not operate any switches for ventilation fan...

Страница 10: ...should be performed at the same or similar environment as that of the instrument use temperature pressure and humidity If temperature changes sharply during use of the instrument for instance using t...