SENKO pellet AIR stoves
–
Instruction manual
39
5.7.2. AUTOMATIC MODE (
AUTO
)
Unlike the manual mode where you can adjust the heating power, in
automatic mode you
can adjust the room temperature
(
Temp
: 5
– 35°C
).
The room temperature is measured by a probe (P-
figure 31a
)
– black wire,
situated on the stove backside, next to the activation
switch. In order to more realistic room temperature
measuring, it is necessary to
ensure that the probe
is located away from the chimney
.
You can connect the stove also to
the
room thermostat
. Thermostat
wires must be attached to the JC connection on the back of the stove. In
this case the probe (
P
) at the back of the stove will no longer have its
function. The authorized individual must
activate the thermostat in the
technical menu
.
The stove will automatically change the heating power to keep the set
room temperature constant.
Warm air ventilator speed changes
automatically to accommodate current heating power.
By pressing any key on the control panel, selection screen will appear
on the display (
figure 31b
). If the system is in manual mode, pressing the
upper left key (
Mode
) will
change the mode into automatic
(
AUTO
).
The stove will operate on
maximum power until the set
temperature is achieved.
Once the set room temperature is achieved,
the stove will gradually reduce the heating power to minimum.
When
the room temperature drops below the set value, the stove gradually returns
to maximum heating power to reach the set temperature.
After each ignition, the stove returns to the operating mode
selected before the last shut down !
Figure 31b
Mode:AUTO Menu
Temp:20°C Fan:A
Figure 31a
P