SENKO pellet AIR stoves
–
Instruction manual
30
Useful information
for understanding the functioning of the control panel:
Backlight of the control panel screen turns off after approximately
30 seconds unless any key is pressed. To turn on the backlight
again, press any key on the control panel.
The display always shows the stove operating status (ON, OFF,
IGNITION, SHUT DOWN
…) which indicates the currently activated
settings (CHRONO, SLEEP
, AUTO, ECO…).
By pressing any of the 4 keys around the screen (1 2 3 4) you are
accessing the menu in which you can alter the operational
parameters of the stove (heating power
– FIRE, ventilator speed –
FAN, room heating temperature
– TEMPERATURE, manual or
automatic mode
– MANU / AUTO, etc.). Each of these 4 keys has
its assigned function, i.e. they directly refer to words displayed on
the screen in the immediate vicinity of each of these keys (e.g. the
word in the lower left corner refers to key 2).
When changing the heating power it is important to note that
the ascending power changes with a lag of 1 minute, while the
descending power changes with a delay of 4 minutes.
Should you, during alteration of a parameter in any menu, fail to
confirm the change by pressing key 3, and leave the key inactive
for 10 seconds, START display appears and the change is NOT
saved.
Should you, in any menu, shortly press key 5 (on/off), START
display will automatically appear on your screen (display of stove
operating status) without saving any changes not confirmed by
„OK“ key.