42
Step
2
:
Remove
the
inverter
from
the
rear
panel
.
Step
3
:
Remove
the
rear
panel
.
Before
removing
DC
input
connector
,
double
check
DC
input
switch
is
turned
to
OFF
to
avoid
inverter
damage
and
personal
injury
.
Fan
Maintenance
WARNING
25K/28K/30K there are external FAN, check periodically heat sink and the inlet / outlet of
external FAN, clean them, and ensure that they are free from dust and blockage. If any
abnormal with the FAN, please replace it.
PV FUSE is in-built, if any warning display that the FUSE is melt, disconnect AC breaker, and
switch off DC switcher to OFF; pull out all DC input strings, wait at least 10 minutes after the
inverter is powered off. Then open panels of the inverter, identify the melt FUSE using multi-
meter, and replace them, install the panels, tighten the screws of invert, and restart the
inverter.
When replacing the FUSE, be sure to unplug all the dc input group
terminals of the inverter, otherwise there will be a danger of electric
shock.