10
3
Storage
This
chapter
describes
the
storage
requirements
for
the
inverter
.
The
following
storage
instructions
apply
if
the
PV
inverter
will
not
be
deployed
immediately
:
>
Do
not
unpack
the
inverter (put
desiccant
in
the
original
box
if
the
PV
inverter
is
unpacked)
.
>
Store
the
PV
inverter
at
a
temperature
range
of -40
℃
to +70
℃
and
with
the
relative
humidity
of 0% to 100% (no condensing).
>
The
PV
inverter
should
be
stored
in
a
clean
and
dry
place
and
be
protected
from
dust
and
water vapor corrosion.
>
A maximum of four layers of inverters can be stacked.
>
Do
not
position
the
inverter
at
a
front
tilt
,
excessive
back
tilt
,
or
side
tilt
,
or
upside
down
.
>
Conduct
periodic
inspection
during
storage
.
Replace
the
packing
materials
immediately
if
any
rodent bites are found.
>
Ensure
that
qualified
personnel
inspect
and
test
the
inverter
before
use
if
it
has
been
stored
for a long time.