Seneca ZC-24DI Скачать руководство пользователя страница 5

ENGLISH 5/8

MI001515-E

USB Interface

High speed, configurable, digital input

counters (Max Frequency: 10 kHz)

Generic digital inputs

ZC-24DI

ZC-24DI

ZC-24DI

DIN 1 (Count 1)

DIN 9

DIN 17

DIN 2 (Count 2)

DIN 10

DIN 18

DIN 3 (Count 3)

DIN 11

DIN 19

DIN 4 (Count 4)

DIN 12

DIN 20

DIN 5 (Count 5)

DIN 13

DIN 21

DIN 6 (Count 6)

DIN 14

DIN 22

DIN 7 (Count 7)

DIN 15

DIN 23

DIN 8 (Count 8)

DIN 16

DIN 24

1

17

5

24

24

32

32

2

18

6

3

19

13

4

20

14

9

25

21

10

26

22

11

27

29

12

28

30

7

7

7

23

23

23

15

15

15

31

31

31

16 V

Output

24

32

16 V

Output

16 V

Output

       Do not connect this

terminals to power supply

The module has a microUSB connector, you can configure it through APP and/or software.

For more information please see www.seneca.it/prod

//zc-24di.

ucts

CU-A-MICRO-OTG

CU-A-MICROB

CU-A-MICROB

USB

Содержание ZC-24DI

Страница 1: ...it All technical data contained in the document may be modified without prior notice Content of this documentation is subject to periodical revision Contents General Specifications Technical Specifications Installation Rules Electrical connections CAN Bus connection rules DIP switches settings Programming Significant Components Position Leds Signallings Factory Settings Decommissioning and disposa...

Страница 2: ...for the device configuration Power supply and Canopen MODBUS wiring connections facilitated by means of a bus that can be housed in the DIN rail IEC EN 60715 1500 V Isolation among input output power supply and CAN MODBUS interface Increments of counters individually configurable on the rising or falling edges of the corresponding digital input Overflow indication available for each counter Preset...

Страница 3: ...hat obstruct the ve nt il at io n sl o t s Ne ve r i ns ta ll t h e m o dule s ne a r hea t s our ce s We recommend installation in the lower part of the control panel ADDITIONAL NOTES Use in environment with 2 or less pollution degree The module complies with the following standards EN61000 6 4 electromagnetic emission industrial environment EN61000 6 2 electromagnetic immunity industrial environ...

Страница 4: ... two bus terminators modules Drop Length maximum length of a drop line as a function of the Baud Rate Please see Scheme 1 Z PC DINAL1 35 Accessory When Z PC DINAL1 35 accessory is u s e d t h e p o we r s u p p l y a n d communication signals may be provided by the terminals block into t h e D I N r a i l s u p p o r t The figure shows the meaning of the terminal blocks and the position of the DIP...

Страница 5: ...13 DIN 21 DIN 6 Count 6 DIN 14 DIN 22 DIN 7 Count 7 DIN 15 DIN 23 DIN 8 Count 8 DIN 16 DIN 24 1 17 5 24 24 32 32 2 18 6 3 19 13 4 20 14 9 25 21 10 26 22 11 27 29 12 28 30 7 7 7 23 23 23 15 15 15 31 31 31 16 V Output 24 32 16 V Output 16 V Output Do not connect this terminals to power supply The module has a microUSB connector you can configure it throughAPP and or software For more information ple...

Страница 6: ...2 3 4 5 6 7 8 910 Baud Rate kbps 1 2 3 4 5 6 7 8 910 binary number x x x x x x x 20 2 4 x x x 0000001 ADD 001 x x x x x x x 50 4 8 x x x 0000010 ADD 002 x x x x x x x 125 9 6 x x x 0000011 ADD 003 x x x x x x x 250 19 2 x x x 0000100 ADD 004 x x x x x x x 500 38 4 x x x 0000101 ADD 005 x x x x x x x 800 57 6 x x x x x x x 1000 115 2 x x x 1111111 ADD 127 x x x x x x x Software programmed x x x Sof...

Страница 7: ...ing ON The device is receiving SIGNIFICANT COMPONENTS POSITION Screw terminals LED IDC10 Connector IDC10 DIP Switches The screw terminals numbering the LEDs position on frontal panel the rear IDC10 connector for DIN rail connection and the DIP Switch on the side are illustrated below Frontal Panel Side Panel IDC10 CAN MODBUS and Power Supply ON ET002803C Factory Preset ModBus RTU PROTOCOL FRONT PA...

Страница 8: ...rameters are possible by EASY SETUP software please see www seneca it download area For more information about a list of all register and their function Pease see USER manual FACTORY SETTINGS All DIP switch OFF MODBUS Protocol Communication parameters 38400 8 N 1 Addr 1 Filter active on the 24 Digital inputs and Filter value 100Hz All dip switch OFF except and SW2 ON SW4 ON CANopen Protocol Commun...

Отзывы: