background image

MI002273-E

ENGLISH 2/8

1.0 DISCLAIMER

Before executing any operation it’s mandatory to read all the content of this 
user manual. Only electrical-skilled technicians can use the module 
described in this user Manual; it is responsibility of the installer to verify that 
the installation complies with safety standards.

Only the Manufacturer is authorized to repair the module or to replace 
damaged components.

No warranty is guaranteed in connection with faults resulting from improper 
use, from modifications or repairs carried out by Manufacturer-unauthorised 
personnel on the module, or if the content of this user Manual is not followed.

2.0 DESCRIPTION AND GENERAL FEATURES

2.1 Description

Single-phase switching power supply for Seneca modules: it can be installed on  DIN 
46277 rail. Input voltage range: 100-260 Vac @ 47 - 63 Hz; output: 24 Vdc @ 1,5 A.

2.2 General features

AC input rated voltage from 110 Vac to 230 Vac @ 47 Hz-63 Hz, 0.7 A

DC input rated voltage from 110 Vdc to 315 Vdc @ 0.7 A

Output voltage: 24 Vdc ± 2% (it is possible the redundancy between two Z-SUPPLY 
through connection in parallel of their respective output, ONLY by IDC10 connector)

Output maximum-current: 1.5 A

Internal fuse: 1.25 A, type T (delayed), for the protection against of the over-current and 
over-voltage

Quick installation on DIN 46277 rail

Isolation up to 3 KVac between input voltage and output voltage

LED to signal the status of the output voltage and power supply

It is possible to supply the modules of the Seneca Z-PC Line through IDC10 connector

3.0 TECHNICAL SPECIFICATIONS

3.1 General specifications

Efficiency

87% @ 1.5 A, 230 V, cosΦ 0,7

Power supplied

36 W max

Isolation between: input, output

3 KVac / 60 s

Over-voltage category/Pollution 
degree

II/2

Power consumption (no load)

< 1.4 W

Power consumption (full load)

< 6.6 W

Current trip protection

1.7 A

This module is designed for connection to hazardous electric voltages.
Ignoring  this  warning  can  result  in  severe  personal  injury  or  mechanical 
damage.

Содержание Z-SUPPLY

Страница 1: ...relay power good 3 5 Enclosure 3 6 Connectors 3 7 Environmental conditions 3 8 Standards 3 9 Module layout 4 0 Preliminary instructions for use 5 0 Installation 5 1 Installation on removal from DIN 46...

Страница 2: ...ge from 110 Vac to 230 Vac 47 Hz 63 Hz 0 7 A DC input rated voltage from 110 Vdc to 315 Vdc 0 7 A Output voltage 24 Vdc 2 it is possible the redundancy between two Z SUPPLY through connection in paral...

Страница 3: ...hut down voltage 90Vac Derating curve for output the derate starts at 55 C for 0 02 A K Temperature C 20 0 55 70 1 5 A 1 2 A Current A 3 4 Output relay power good Relay type N O with 1 A 30 Vdc resist...

Страница 4: ...vertical position No operation on the module is allowed while it is power on It is forbidden to install the module near heat emitting devices It is reccomended that the use and installation operations...

Страница 5: ...and DIN rail slot Fig 1c and Fig 1d 12 11 9 8 24Vdc 0 Vdc 7 P E From OUT of the Z SUPPLY 0 VDC CANH A GNDSHLD G N D B L A H S H D A C A C P E Fig 1c Z PC DIN Slot CANL B GND From OUT of the Z SUPPLY...

Страница 6: ...2 2 0 5 mm 2 5 mm 6 2 24 Vdc output by screw terminals The output is available on the screw terminals M7 M8 M9 24 Vdc and M10 M11 M12 0 V dc as shown in Fig 4 The output is protected against the curre...

Страница 7: ...ernally connected at the end of the IDC10 output so it is possible to connect more Z SUPPLY modules in parallel ONLY if the redundant outputs are connected by IDC10 IT IS FORBIDDEN to connect more Z S...

Страница 8: ...WEEE directive This symbol found on your producr or on its packaging indicates that this product should not be treated as household waste when you wish to dispose of it Instead it should be handed ove...

Отзывы: