background image

ENGLISH - 8/8

MI004531-I

Code

Description

Z-UMTS

HSPA+ unit with RTU 

multiprotocol datalogger.

Z-PC-DINAL1-35

DIN rail support with screw terminals P= 35 mm.

Z-PC-DIN1-35

DIN rail with one slot support for rear connector P= 35 mm.

A-GSM

External GSM antenna dual band adhesive, cable 3,2 m.

FD01 

Photodetector for pulse counter, MAX frequency 10 Hz.

ORDER CODES

DIP-SWITCHES

SW1

All the DIP-Switches to OFF    

 position.

For further informations please refer to: USER MANUAL

SW2

RS232 or RS485 configuration

on terminals 10-11-12 (serial port COM 2)

RS232

ON

RS485

OFF

CONFIGURATIONS

DI4

DI3

DI2

DI1

DO2

DO1

485
ACT

19 20 21

22 23 24

USB

10 11 12

13 14 15

16 17 18

1

2

4

5

6

S

SENECA

3

ETH
LNK

ETH
ACT

SD

PWR

ETHERNET

ANTENNA

Z-UMTS

S

SENECA

ETH

USB

The module has a RJ45 socket on frontal panel.
Note: Inserting the RJ45 10/100 Base T Ethernet plug make sure that the
connector is securely latched, or before inserting the cable into the RJ45
connector, move the protective rubber. The picture shows how to Insert the 
RJ45 connector.     

For further information, refer to the 

USER MANUAL.

The module has a serial USB micro port on the lower side.
The picture shows how to Insert the micro USB plug into the micro USB
side socket.           For further information, refer to the USER MANUAL.

RJ45 ETHERNET AND USB CONNECTIONS

Inserting the SIM card
into the frontal slot.
If the SIM card is properly
inserted then protrudes
from the frontal panel of
about 4.5mm.

Inserting the MicroSD or
the microSHDC, into the
side slot. Max 32 GB.
Push-push connector
for insertion and
removal.

SIM-CARD AND SD-CARD INSERTING

Technical support

[email protected]

Product Informations

[email protected]

CONTACTS

Содержание Z-LOGGER3

Страница 1: ...ed in it This informations may be modified or integrated for technical and or commercial requirements SENECA s r l Headquarters Via Austria 26 35127 PADOVA ITALY Phone 39 049 8705355 8705359 Fax 39 04...

Страница 2: ...F Network Searching or Missing Signal OFF Modem OFF LED SIGNALING ON FRONT PANEL Dimensions L H W 35 x 100 x 111 mm with terminals Weight 250 g Case Material PA6 black color 100 mm Z UMTS Connector Re...

Страница 3: ...4 Energized 12V closed contact OFF Digital Input 4 De energized open contact PWR STS Green ON Z UMTS ON inactive log status ready Slow Blinking 2 8 sec ON 0 4 sec OFF Z UMTS active log status normal S...

Страница 4: ...argeable batteries CONNECTIONS Removable three pole screw terminal pitch 5mm 2 for cable up to 2 5 mm rear IDC10 front RJ45 Micro USB and Antenna SMA POWERSUPPLY Voltage Power absorbed 19 40 V or 19 2...

Страница 5: ...ure 40 C and one of the severe operating condition exists The operating temperature 35 C and two of the severe operating conditions exist Disposal of electrical electronic equipment applicable through...

Страница 6: ...C10 connector into a free slot of DIN rail accessory as you can see in fig 1a the insertion is one way only because the connectors are polarized 3 To secure the module to the IEC EN 60715 DIN rail tig...

Страница 7: ...lations transformers inverters motors induction ovens etc POWERSUPPLY The power supply must be connected to terminals 2 and 3 The supply voltage must be between 19 and 40V any polarity or between 19 a...

Страница 8: ...ETH USB The module has a RJ45 socket on frontal panel Note Inserting the RJ45 10 100 Base T Ethernet plug make sure that the connector is securely latched or before inserting the cable into the RJ45...

Отзывы: