Seneca Z-LOGGER3 Скачать руководство пользователя страница 3

ENGLISH - 3/8

MI004531-E

LED

Status

LED’s meaning

DI1

(Red)

ON (NPN)

Digital Input 1: Energized (GND closed contact)

ON (PNP)

Digital Input 1: Energized (+12V closed contact)

OFF

Digital Input 1: De-energized (open contact)

DI2

(Red)

ON (NPN)

Digital Input 2: Energized (GND closed contact)

ON (PNP)

Digital Input 2: Energized (+12V closed contact)

OFF

Digital Input 2: De-energized (open contact)

DI3

(Red)

ON (NPN)

Digital Input 3: Energized (GND closed contact)

ON (PNP)

Digital Input 3: Energized (+12V closed contact)

OFF

Digital Input 3: De-energized (open contact)

DI4

(Red)

ON (NPN)

Digital Input 4: Energized (GND closed contact)

ON (PNP)

Digital Input 4: Energized (+12V closed contact)

OFF

Digital Input 4: De-energized (open contact)

PWR/STS

(Green)

ON 

 

Z-UMTS ON inactive log (status=ready)

Slow Blinking

2.8 sec ON 0.4 sec OFF



Z-UMTS active log (status=normal)

Slow Blinking

1.6 sec ON 1.6 sec OFF



Battery powered inactive log (status=battery backup)

Medium Blinking

0.8 sec ON 0.8 sec OFF



Low battery warning

Fast Blinking

0.2 sec ON 0.2 sec OFF



Z-UMTS initializing or shutdown

Fast Blinking

0.6 sec 



 1 sec OFF



Error, please refer to the diagnostic

OFF

 

Z-UMTS OFF

SD/STS

(Red)

ON 

 

SD card mounted in the right way

Medium Blinking

0.8 sec ON 0.8 sec OFF



SD card activity

Fast Blinking

0.2 sec ON 0.2 sec OFF



SD card error

OFF

 

SD card not present

ETH LNK

(Green)

Blinking

RJ45 connection activated

ETH TRF

(Yellow)

Blinking

Traffic on Ethernet port

LED SIGNALING ON FRONT PANEL

Содержание Z-LOGGER3

Страница 1: ...ed in it This informations may be modified or integrated for technical and or commercial requirements SENECA s r l Headquarters Via Austria 26 35127 PADOVA ITALY Phone 39 049 8705355 8705359 Fax 39 04...

Страница 2: ...F Network Searching or Missing Signal OFF Modem OFF LED SIGNALING ON FRONT PANEL Dimensions L H W 35 x 100 x 111 mm with terminals Weight 250 g Case Material PA6 black color 100 mm Z UMTS Connector Re...

Страница 3: ...4 Energized 12V closed contact OFF Digital Input 4 De energized open contact PWR STS Green ON Z UMTS ON inactive log status ready Slow Blinking 2 8 sec ON 0 4 sec OFF Z UMTS active log status normal S...

Страница 4: ...argeable batteries CONNECTIONS Removable three pole screw terminal pitch 5mm 2 for cable up to 2 5 mm rear IDC10 front RJ45 Micro USB and Antenna SMA POWERSUPPLY Voltage Power absorbed 19 40 V or 19 2...

Страница 5: ...ure 40 C and one of the severe operating condition exists The operating temperature 35 C and two of the severe operating conditions exist Disposal of electrical electronic equipment applicable through...

Страница 6: ...C10 connector into a free slot of DIN rail accessory as you can see in fig 1a the insertion is one way only because the connectors are polarized 3 To secure the module to the IEC EN 60715 DIN rail tig...

Страница 7: ...lations transformers inverters motors induction ovens etc POWERSUPPLY The power supply must be connected to terminals 2 and 3 The supply voltage must be between 19 and 40V any polarity or between 19 a...

Страница 8: ...ETH USB The module has a RJ45 socket on frontal panel Note Inserting the RJ45 10 100 Base T Ethernet plug make sure that the connector is securely latched or before inserting the cable into the RJ45...

Отзывы: