Code

Description

S117P1

RS232/USB, TTL/USB, RS485/USB asynchronous and optoisolated serial converter

EASY-USB

USB - UART TTL converter

CS-RJ10-AMP

Spare cable for S117P1 and EASY-USB converters

EASY-LP

Software configurator for loop powered devices

EASY-SETUP

Suite for all programmable SENECA devices

CUSTOMIZATION OF THE INTERPOLATION CURVE

The EASY SETUP software allows the configuration of  the T121 module in order to linearise also the 
sensors included in the above table (Custom) if their operating range is within the indicated limits.
The curves of some additional sensors, such as Ni1000, are already included in the software.
There is also a tool to properly configure the S311A product for T121 module connection.

TABLE OF USER CONFIGURABLE SENSOR TYPES

Sensor

Type

Operating range

Custom

mV

± 150 mV

RTD 

Ω

< 400 

 400 

Ω

RTD < 1760 

Ω

 1760 

Ω

TC

± 150 mV

Potentiometer

500 

 100 k

Ω 

Ω

Resistance 

Ω

< 400 

 400 

Ω

Resistance < 1760 

Ω

 1760 

Ω

Содержание T121

Страница 1: ...d technologies described in it This informations may be modified or integrated for technical and or commercial requirements SENECA s r l Via Austria 26 35127 PADOVA ITALY Tel 39 049 8705355 8705359 Fa...

Страница 2: ...m 2 A 13 bit 102 5 of full scale see Over range table Programmable between 3 4 and 23 mA see Fault table 30mA POTENTIOMETER INPUT Potentiometer value Energizing current Input impedance Sensor fault de...

Страница 3: ...aused by EMI 300 ms 620 ms 60 dB at 50 and 60 Hz 0 5 EMI ElectroMagnetic Interference STANDARDS EN61000 6 4 Electromagnetic emission industrial environment EN61000 6 2 Electromagnetic immunity industr...

Страница 4: ...ple J K T N E 0 05 0 05 0 5 C Thermocouple B R S 0 05 0 05 1 C RTD 0 05 0 05 0 1 C Resistor 0 05 0 05 40 m Resistor 0 05 0 05 200 m Voltage 0 05 0 05 15 V Potentiometer 0 05 0 05 0 01 EMI ElectroMagne...

Страница 5: ...tweenmoduleandprobe youshouldrememberthatthisconnection introduces an error in the measurement which can be removed by software programming equivalent to the resistance contributedbytheconnectioncable...

Страница 6: ...ction 2wires 3wiresand4wires Measurementfilter disabledorenabled Output Normal 4 20mA orreversed 20 4mA Inputtype Cableresistancecompensationfor2wiresmeasurement Outputcurrentvalueincaseoffailure Valu...

Страница 7: ...n case of fault Over Range To terminals 3 and 4 YES enabled NO disabled NO disabled K 0 C 1000 C 21 mA YES limited output between 2 5 and 102 5 FACTORY SETTINGS 2 PROGRAMMING CONNECTOR ACCESS 2 CONNEC...

Страница 8: ...ces CUSTOMIZATION OF THE INTERPOLATION CURVE The EASY SETUP software allows the configuration of the T121 module in order to linearise also the sensors included in the above table Custom if their oper...

Отзывы: