![Sencore DMG 4000 Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/sencore/dmg-4000/dmg-4000_user-manual_1239214072.webp)
Page | 72
PORT SETTINGS
Enabled
Enabled/disable RF output.
CW Carrier Test
Mode
Enable CW test mode to disabled modulation and only output a single carrier
wave.
RF Source
Status showing the active source of the RF output. The status can be Main,
Backup or Mute.
Front Switch
Status of the front switch position. Switch position can be Auto, Main, Backup
or Mute.
Software Switch
Dropdown to select RF source. Only applicable if Front Switch is set to Auto. If
Software Switch is set to auto the backup can be switched in if the backup is
present and the “failure index” is above 100,
SEE
REDUNDANCY
CHAPTER
.
Backup Present
Threshold
Define RF level threshold for backup present detection.
Backup
Backup present status. Status is Present if measured RF level of backup is
higher than configured threshold.
Backup Port
Level
Status of current measured backup RF level.